Field Service Ver. 1.0 Apr. 2005
5. Introduction
15
AD-504
T
roubleshooting
5.1.5
Motor
Step
Check
Result
Action
1
Does the LOCK signal switch to H when the machine goes into
standby?
NO
Replace the control
board. Replace the
motor.
2
Does the REM signal of the master board change from H to L
when the motor is turned on?
YES
Replace the motor.
NO
Replace the control
board.
Step
Check
Result
Action
1
Does the input signal of the master board change from H to L
when the motor is turned on? (The input signal differs depend-
ing on the rotation direction.)
YES
Replace the motor.
NO
Replace the control
board.
Step
Check
Result
Action
1
Are the relay connector of the motor and the print jack of the
control board correctly connected?
YES
Replace the motor or
the control board.
NO
Connect the connec-
tor or the print jack.
4025T526AA
GND
REM
LOCK
2
1
3
4025T525AA
4025T527AA
bizhub_162_210_FS.book 15 ページ 2005年4月18日 月曜日 午前10時5分
Содержание AD-504
Страница 1: ...SERVICE MANUAL 2005 04 Ver 1 0 AD 504 THEORY OF OPERATION...
Страница 2: ......
Страница 4: ......
Страница 6: ...AD 504 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 ii Blank page...
Страница 8: ...1 Product specification Theory of Operation Ver 1 0 Apr 2005 2 AD 504 Outline Blank page...
Страница 15: ...SERVICE MANUAL 2005 04 Ver 1 0 FIELD SERVICE AD 504...
Страница 16: ......
Страница 18: ......
Страница 22: ...1 Product specification Field Service Ver 1 0 Apr 2005 2 AD 504 General Blank page...
Страница 28: ...2 Other Field Service Ver 1 0 Apr 2005 8 AD 504 Maintenance Blank page...
Страница 32: ...4 Service Mode Field Service Ver 1 0 Apr 2005 12 AD 504 Adjustment Setting Blank page...