Field Service Ver. 1.0 Apr. 2005
4. Service Mode
11
AD-504
Adjustment / Setting
4.2
Setting in the Service Mode
4.2.1
SERVICE’S CHOICE
A. LOOP ADJUST (DUPLEX)
Purpose/Use
To adjust the length of the loop formed in the paper before the Synchronizing Roller.
✽
When a skew feed, fold, or misfeed of paper occurs
✽
When variations in the amount of void on the leading edge occurs
Setting/
Procedure
Setting range: -3.9 to 3.9 mm (1 step: 0.6 mm)
Adjustment
Procedure
1.
Call Service’s Choice of Service Mode to the screen.
2.
Select “Loop Adjust (Duplex)” and press the [Yes] key.
3.
Using [
▲
/
▼
] key, select the desired setting value.
4.
Press the [Yes] key to validate the setting value selected in step 3.
Adjustment Instructions
• Try a different setting value until there are no variations in the amount of void on
the leading edge, and paper skew, fold, or misfeed.
bizhub_162_210_FS.book 11 ページ 2005年4月18日 月曜日 午前10時5分
Содержание AD-504
Страница 1: ...SERVICE MANUAL 2005 04 Ver 1 0 AD 504 THEORY OF OPERATION...
Страница 2: ......
Страница 4: ......
Страница 6: ...AD 504 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 ii Blank page...
Страница 8: ...1 Product specification Theory of Operation Ver 1 0 Apr 2005 2 AD 504 Outline Blank page...
Страница 15: ...SERVICE MANUAL 2005 04 Ver 1 0 FIELD SERVICE AD 504...
Страница 16: ......
Страница 18: ......
Страница 22: ...1 Product specification Field Service Ver 1 0 Apr 2005 2 AD 504 General Blank page...
Страница 28: ...2 Other Field Service Ver 1 0 Apr 2005 8 AD 504 Maintenance Blank page...
Страница 32: ...4 Service Mode Field Service Ver 1 0 Apr 2005 12 AD 504 Adjustment Setting Blank page...