Theory of Operation Ver. 1.0 Apr. 2005
12. Fusing section
37
bizhub 160/160f bizhub 161/161f
Composition/Operation
12.2 Fusing Temperature Control
12.2.1
Temperature Changes (Plain Paper Having a Length of 186 mm or More)
12.2.2
Temperature Control
• The fusing temperature is increased to a predetermined level during the warm-up cycle.
• The warm-up control is provided when power is turned ON, the Front Door is opened and
closed, and the Energy Save mode is canceled.
• In the standby state, the fusing temperature is set to a level (130 °C) lower than that dur-
ing a print cycle, thereby cutting down power consumption.
• The temperature control mode when the control is resumed (when power is turned ON,
the Front Door is opened and closed, or the Energy Save mode is canceled) is set
according to the mode and the fusing temperature valid before the interruption.
• In the Energy Save mode, the Fusing Roller Heater Lamp is turned OFF to reduce power
consumption.
Thermistor-detected temperature
at temperature control start
Less than 50 °C
50 °C to 125 °C
125 °C or more
Mode before
temperature
control
Power OFF, Front
Door open/close
Mode 0
Mode 0
Mode 0
Mode 0
Mode 1
Mode 2
Mode 3
Mode 1
Mode 1
Mode 2
Mode 2
Mode 3
Mode 3
130 °C
200 °C
Fusing Roller
T
e
mp
er
at
ure
Warm-up
Mode 1:
300 sec.
Mode 2:
208 sec.
Mode 3
In standby
During print cycle
(600 dpi)
Temperature detected by Thermistor
Mode 0:
180 sec.
bizhub_160_160f_161_161f_TO.book 37 ページ 2005年4月18日 月曜日 午後4時22分
Содержание A0XY026
Страница 1: ...SERVICE MANUAL 2005 04 2005 04 Ver 1 0 Ver 1 0 THEORY OF OPERATION...
Страница 20: ...SERVICE MANUAL 2005 04 Ver 1 0 THEORY OF OPERATION Main Unit...
Страница 21: ......
Страница 23: ......
Страница 76: ...SERVICE MANUAL 2005 04 Ver 1 0 DF 501 THEORY OF OPERATION...
Страница 77: ......
Страница 79: ......
Страница 81: ...DF 501 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 ii Blank page...
Страница 90: ...SERVICE MANUAL 2005 04 Ver 1 0 PF 501 THEORY OF OPERATION...
Страница 91: ......
Страница 93: ......
Страница 95: ...PF 501 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 ii Blank page...
Страница 97: ...1 Product specification Theory of Operation Ver 1 0 Apr 2005 2 PF 501 Outline Blank page...
Страница 101: ...2 Operation Theory of Operation Ver 1 0 Apr 2005 6 PF 501 Composition Operation Blank page...
Страница 102: ...SERVICE MANUAL 2005 04 Ver 1 0 NC 501 SU 502 THEORY OF OPERATION...
Страница 103: ......
Страница 105: ......
Страница 107: ...NC 501 SU 502 Outline Composition Operation Theory of Operation Ver 1 0 Apr 2005 ii Blank page...
Страница 109: ...1 Product specifications Theory of Operation Ver 1 0 Apr 2005 2 NC 501 SU 502 Outline Blank page...
Страница 115: ...3 Electrical components Theory of Operation Ver 1 0 Apr 2005 8 NC 501 SU 502 Composition Operation Blank page...