Chapter 2 Before the Repair
2-29
Initialization of the Mechanical Unit
•
Check if there is cassette inside the equipment and close the shutter.
•
Move the unit to the initial position.
•
Shutter: Closed
•
Receiver: Receiver
home
position
•
Justifier guide:
Justifier home position
•
Push plate unit:
Transporter home position
•
Subscan unit:
Subscan home position
Initialization sequence of the mechanical unit
Check Cassette Detection
Sensor
Shutter Open
End
Shutter Close
Move Justifier Minutely Toward
Cassette Fixing Direction
Move Justifier
to Justifier HP
Transporter
at Read Position?
Shutter Close?
Jam Evacuation
Action
Wait for Door
Open
Wait for Door
Close
Justifier at HP
Position?
Move Transporter
to Read Position
Move Transporter
to HP
Start
Synchronize
No
Yes
No
Yes
Move Down
Receiver Minutely
Move Receiver
to HP
Receiver at
HP Position?
No
Yes
With Cassette
No
Without Cassette
Yes
Subscan Unit
at Mechanical HP
Position?
No
Yes
Move Subscan
Unit to
Mechanical HP