20
401063/I
Rotary Switch Functions
The Mk2 Operating Panel is fitted with three rotary switches. The switches are
identified with numbers. Each switch can be assigned a function related to range,
gain, bearing or tilt.
Under
Rotary Switch Options
, assign one function to each rotary switch on the
Operating Panel. The following functions can be assigned:
Horizontal Range
This is the range setting in the
Horizontal
view.
Vertical Range
This is the range setting in the
Vertical
view.
Inspection Range
This is the range setting in the
Inspection
view.
Horizontal Range 2
This is the range setting in the
second Horizontal
view when a "dual"
presentation mode is used.
Vertical Range 2
This is the range setting in the
second Vertical
view when a "dual"
presentation mode is used.
Plane Range
This is the range setting in the
Plane
view.
Active Ping Range
This is the range setting in the currently active view.
Active Ping Gain
This is the gain setting in the currently active view
Active Ping Bearing
This is the bearing setting in the currently active view.
Active Ping Tilt
This is the tilt setting in the currently active view