
IS12 Mega
20
E04252
3.2.2 NMEA Mode (Mode 2)
This mode should be selected if the Mega instrument is to be
used as an NMEA data repeater with no IS12 master units. In
this mode, the Mega will display the following data -
- NMEA0183 instrument data
- NMEA0183 navigational data
In this mode only the NMEA terminals are used to link the
Mega to any master units - the network ports are only used to
supply power to the display. No data is received or transmitted
to any IS12 units connected to the Mega via the network ports.
The NMEA Out terminals will retransmit the following data -
- NMEA0183 instrument data
- NMEA0183 navigational data
NMEA In
Instrument & Nav Data
NMEA Out
Instrument & Nav Data
Fig 3.3 - Installation example - NMEA Mode
12v in
To switch between IS12 & NMEA modes, enter calibration
mode and press
once (the display will show “MODE CAL”.
Press (INFO) to accept.
The large digits on the display will show “1” for IS12 Mode or
“2” for NMEA Mode. Press
or
to change modes then
to accept and return to the calibration menu.
NOTE
Press
to exit to the main calibration menu at any point.
Содержание Simrad IS12
Страница 1: ...A L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Y ...
Страница 2: ......
Страница 3: ...Instruction Manual III Simrad IS12 Mega Instrument M A N U A L ...
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ...A L W A Y S A T T H E F O R E F R O N T O F T E C H N O L O G Y www simrad com ...