484164/A
71
• Electrical tape
• Cable ties
Context
The transducer cable is attached to the transducer, and it has a fixed length. The bushing and
the associated parts are included in the delivery.
Note
All necessary precautions must be made to avoid damage to the cable while pulling it through
the steel conduit. Make sure that all welding has been finalized before you pull the cable
through the steel conduit. Heat may cause serious damage to the cable and the transducer.
These items are all provided as a part of the transducer delivery.
A
Bushing penetrates the hull plating
B
Washer
C
Rubber gasket
D
Packing nipple
Procedure
1
Make sure that the steel conduit has been finished, and that all welding has been
finalized.
2
Lower the fish tape (wire pulling tool) down from the top of the steel conduit, and
through the bushing.
3
Make sure that the rubber gasket, washers and packing nipple are threaded onto the
transducer cable.
These items are kept between the bushing and the transducer.
Содержание Simrad CP200-5C
Страница 1: ...Photo by Gatis Marcinkevics kongsberg com simrad Simrad CP200 5C INSTALLATION MANUAL ...
Страница 2: ......
Страница 55: ...484164 A 53 Related topics Preparations page 22 Acoustic noise page 45 Preparations ...
Страница 58: ...56 484164 A Related topics Preparations page 22 Simrad CP200 5C Installation Manual ...
Страница 99: ...484164 A 97 Related topics Installing the transducer page 57 Drawing file page 94 Drawing file ...
Страница 101: ...484164 A 99 Drawing file ...
Страница 102: ...100 484164 A Related topics Installing the transducer page 57 Drawing file page 94 Simrad CP200 5C Installation Manual ...
Страница 104: ...102 484164 A Related topics Installing the transducer page 57 Drawing file page 94 Simrad CP200 5C Installation Manual ...
Страница 110: ... 2022 Kongsberg Maritime ...