Instruction Manual
19
E03766 Issue 2.0
3.6 Troubleshooting
These simple checks should be carried out before seeking tech-
nical assistance and may save time and expense.
Before contacting your servicing agent please obtain the radio’s
serial number and the software iteration – this is shown in the
large digits on the display for 2 seconds after the radio is turned
on.
Symptom
Possible cause
Remedy
Unit will not switch on
• Battery not charged
• Re-charge battery
• Battery not attached correctly
• Ensure battery is fully
to radio
engaged
(see section
2.5)
Scan or Memory Scan
• Noise on the channel is
• Increase squelch level
is locking on a channel
holding the scan
• Inhibit channel from
without a signal
scan
Dual Watch not being
• Priority channel selected
• Select a working
entered
(normally channel 16)
channel
Cannot change channel
• Dual Watch (D/W) engaged
• Exit Dual Watch
Certain channel numbers
• Some channels are restricted
• Consult your national
are not obtainable
and programmed depending
authority for permitted
on country of purchase
channels in your region
Will not transmit
• Scanning or D/W function active
• Exit D/W or scan
Will not transmit on 5W
• Low voltage when full transmit-
• Battery charge low –
but OK on 1W
ting current is drawn
recharge the battery
• Some channels are restricted to
• Consult your national
low power transmission only
authority
Transmissions are
• Damaged antenna
• Replace antenna
persistently weak