RADius 1000 Installation Manual, rev. 5
Installation
21
The connectors on the Processing Unit for the serial lines are of DB-9 male type. Pin layout:
RS-232 RS-422
Pin no. Signal
Pin no. Signal
1 N/C
1 N/C
2 RXD
2 RX+
3 TXD
3 TX+
4 N/C
4 N/C
5 REF
5 REF
6 N/C
6 N/C
7 RTS
7 TX-
8 CTS
8 RX-
9 N/C
9 N/C
3.4.2.2
Power/Connection Shelf
Figure 11 shows the rear panel of the Power/Connection Shelf indicating the terminal rail for
power connection and for Data/LAN.
Figure 11 Power and Data/LAN terminal rails for the Interrogator cables
Figure 12 and Figure 13 illustrate the pin-out for the terminal rail Power and Data/LAN. In
the terminal rail connections for up to four Interrogator Units are included. Connection of
more than one Interrogator Unit is a future optional feature.
+
+
-
Shield
-
+
+
-
Shield
-
+
+
-
Shield
-
+
+
-
Shield
-
Interrogator 1
Interrogator 2
Interrogator 3
Interrogator 4
Pair 1
Pair 2
Pair 1
Pair 2
Pair 1
Pair 2
Pair 1
Pair 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Figure 12 Pin numbers on Power terminal rail
Содержание RADius 1000
Страница 1: ...RADius 1000 Installation Manual Issued 2006 11 30 ...
Страница 2: ...Blank page ...
Страница 4: ...IV Blank page ...
Страница 6: ...VI Blank page ...
Страница 10: ...X Blank page ...
Страница 14: ...RADius 1000 Installation Manual rev 5 Introduction 4 Blank page ...
Страница 40: ...RADius 1000 Installation Manual rev 5 Installation 30 Blank page ...
Страница 50: ...RADius 1000 Installation Manual rev 5 Appendix A Installation worksheet 40 Blank page ...
Страница 58: ...RADius 1000 Installation Manual rev 5 Appendix C Bulgin connector assembly 48 Blank page ...
Страница 60: ...RADius 1000 Installation Manual rev 5 Appendix E Transportation 50 Blank page ...
Страница 62: ...RADius 1000 Installation Manual rev 5 Index 52 Blank page ...