![Kongsberg RADius 1000 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/kongsberg/radius-1000/radius-1000_installation-manual_1992686018.webp)
RADius 1000 Installation Manual, rev. 5
Specifications
8
RADius Transponder Power Supply
Enclosure material:.....................................................................................................Aluminium
Enclosure protection: .......................................................................................................... IP-65
Operating temperature range:................................................................. -15 to +55ºC/5 to 131 F
Operating humidity (max.):................................................................................................. 100%
Storage temperature range: .................................................................-25 to +70ºC/-13 to 158 F
Storage humidity (max.):....................................................................................................... 60%
2.5
Cables
Possible cable types:
Interrogator to Processing Unit Data Cable
Type 1:.....................................Draka type TI (C) 60 V, shipline, 2x2x0.5 mm
2
(Halogen free)
1
Draka part number:......................................................................... 839202, El-number 1045881
Type 2:.................................... Draka type TI (C) 250 V, shipline, 2x2x0.5 mm
2
(Halogen free)
Draka part number:.......................................................................................................... 832002,
Cable resistance, Type1 and Type 2: ........................................................................ 40 Ohm/km
Diameter overall, Type 1:............................................................................................... 6.5
±
0.5
Diameter overall, Type 2:.................................................................................................. 6
±
0.5
Maximum length: ................................................................................................................. 60 m
Flame retardation: ................................................................................................ IEC 60332-1/3
Interrogator Power Cable
Type:.............................................................................................................................. As above
Maximum length: ................................................................................................................. 60 m
Transponder Power Cable
Type:.............................................................................................................................. As above
Maximum length: ............................................................................................................... 200 m
Note!
The data cable must be twisted pair cable! If other cable types are used the
maximum diameter should not exceed 7.5
±
0.5 mm.
1
This type is likely to be obsolete in 2006
Содержание RADius 1000
Страница 1: ...RADius 1000 Installation Manual Issued 2006 11 30 ...
Страница 2: ...Blank page ...
Страница 4: ...IV Blank page ...
Страница 6: ...VI Blank page ...
Страница 10: ...X Blank page ...
Страница 14: ...RADius 1000 Installation Manual rev 5 Introduction 4 Blank page ...
Страница 40: ...RADius 1000 Installation Manual rev 5 Installation 30 Blank page ...
Страница 50: ...RADius 1000 Installation Manual rev 5 Appendix A Installation worksheet 40 Blank page ...
Страница 58: ...RADius 1000 Installation Manual rev 5 Appendix C Bulgin connector assembly 48 Blank page ...
Страница 60: ...RADius 1000 Installation Manual rev 5 Appendix E Transportation 50 Blank page ...
Страница 62: ...RADius 1000 Installation Manual rev 5 Index 52 Blank page ...