Defining the IP address on the Sonar
Processor network adapter
The communication between the Sonar Processor and the Sonar Head is made using a
high-speed Ethernet cable. If a Sonar Processor is not configured to connect to the sonar,
you must define which IP Address and Subnet mask the Ethernet adapter in the Sonar
Processor shall use for this communication.
Prerequisites
This procedure is made for the Microsoft
®
64-bit Windows 10 operating system. It
is assumed that you are familiar with the Windows
®
operating systems, computer
technology, and interface principles.
Context
As long as you do not change the Sonar Processor to another computer, or replace the
network adapter in your Sonar Processor, you will only need to do this once.
Procedure
1
On the Sonar Processor, close the M3 software.
2
Open the
Network Connections
dialog box.
a
In the bottom-left corner of your desktop, select the Windows
®
Start
button.
b
On the menu, select
Settings
.
c
Observe that the
Windows Settings
dialog box opens.
d
Select
Network & Internet
.
e
Select
Change adapter options
.
f
Select the network adapter you are going to use; then right-click and select
Properties
on the short-cut menu.
g
On the list of connections, select
Internet Protocol 4 (TCP/IPv4)
, and then
Properties
.
3
Select
Use the following IP address
, and type the IP address and network mask.
IP Address:
192.168.001.N
(
"N" can be any number from 1 to 254, except 234,
which is the Sonar Head default.
)
Subnet mask:
255.255.255.0
You can leave
Default Gateway
blank.
4
Select
OK