background image

KONEXX Konference Konnector

 

 

OPERATING INSTRUCTIONS - IMPORTANT - PLEASE READ CAREFULLY

The KONEXX Konference Konnector connection device is used to connect a conferencing phone

             to digital or multi-line phone systems through the handset port of the digital or multi-line telephone
             instrument

.

Figure 1:  Typical Installation

1.  Unplug the coiled handset cord from the telephone instrument.
2.  Plug the short cord on the KONEXX into the handset jack on the telephone base (from which you just removed the

coiled cord).

3.  Plug the coiled cord from the handset into the KONEXX jack labeled "HANDSET".
4.  Plug the telephone cord from the conference phone outlet labeled "Line" or "Wall" into the KONEXX jack labeled

"DATA PORT".

5.  Plug the AC adapter into the power jack on the end of the KONEXX product.  The KONEXX Konference Konnector will

not operate without the power supply.

6.  Place the switch on the KONEXX to the #3 position.  Your telephone can now be used in the normal manner.  TRY

YOUR TELEPHONE.

7. 

The "OUTPUT LEVEL" switch on the KONEXX product sets the signal level from your conference phone to the digital
telephone and this switch must be set for the type of telephone instrument you are using. The "#2" position is the
highest level and is used with telephones employing carbon microphones.  Many of the older hotel/motel telephones
are of this type, as are the majority of older standard telephones found in the home.  When the "OUTPUT LEVEL"
switch is set in a position where the level is too high, there will be feedback to the handset earpiece or conference
phone.  Feedback may appear as a buzz, tone or even a loud squeal.  If feedback is present, move the "OUTPUT
LEVEL" switch

 

to the next

 

lower setting until the feedback is eliminated.  "OUTPUT LEVEL" sequence is 2-3-1-4 in

descending order

.

Содержание Konference Konnector

Страница 1: ...anOfAmerica com or shop telephonemanofamerica com TELEPHONE MAN OF AMERICA Earning Your Business Every Step of the Way Specializing in Telecom Equipment of all Brands Carrier Services Technician Services Maintenance Agreements and Purchasing Excess Telecom Equipment I will always do my best to match or beat any competitors bid ...

Страница 2: ...e KONEXX Konference Konnector will not operate without the power supply 6 Place the switch on the KONEXX to the 3 position Your telephone can now be used in the normal manner TRY YOUR TELEPHONE 7 The OUTPUT LEVEL switch on the KONEXX product sets the signal level from your conference phone to the digital telephone and this switch must be set for the type of telephone instrument you are using The 2...

Страница 3: ...B Make sure that your conference phone is in the TONE DIAL mode not in the pulse dial mode C Make sure the telephone handset has been LIFTED OUT OF THE CRADLE D Remember that the KONEXX Konference Konnector must have the AC adapter connected in order to operate E The KONEXX Konference Konnector will not operate with telephones which have the dialer in the handset such as Princess or Trimline phone...

Страница 4: ...hers 1 1 3 1 Isoetec Key systems Digital PBX 3 1 ITT None Specified 2 Iwatsu Omega Omega III Omega IV 2 2 or 3 1 or 4 Kokyo Co Kanda 1 Lanier EKT 220 Elec Key 2 Lexar Telex See Note 2 Macrotel None Specified 4 Mitel Superset SX 200 2 or 3 3 NEC Determ II Determ III Determ IV Electra Freedom Mark II Others 1 or 4 1 or 4 1 2 or 3 1 1 1 MANUFACTURER MODEL SWITCH SETTING Nitsuko Onyx 3 Northcom Premie...

Страница 5: ... 2 2 MANUFACTURER MODEL SWITCH SETTING Toshiba EKT 2000 series EKT 3000 series EKT6000 series Perception Strata Key system Strata Digital 103 series 2 2 3 or 4 3 2 1 or 3 2 or 3 Trillium Panther Talkto 616 2 or 3 2 Vodavi Electronic Key System 3 See Note 1 Walker Marathon Poet 1 or 4 1 Notes 1 The indicated telephone set may require a custom setting performed by Konexx to optimize the audio level ...