![Kone V3F18 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/kone/v3f18/v3f18_installation-instruction_1992339037.webp)
V3F25/18 drive
V3F25/18 drive
Installation Instruction
Installation Instruction
©
© 2004 KONE Co
2004 KONE Corporation
rporation
AM-11.65.020
AM-11.65.020
A
Alll
l
rriig
gh
htts
s
rre
es
se
errv
ve
ed
d..
3
37
7
((4
42
2))
((E
E)
)
2
20
00
04
4--0
01
1--0
08
8
0104
0104
Motor too hot
Motor too hot
Prevents new drive before
Prevents new drive before
the fault is
the fault is corrected.
corrected.
•• Ch
Chec
eck th
k the ma
e mach
chin
ine r
e roo
oom
m
ventilation
ventilation
•• Ch
Chec
eck t
k the
he re
reso
solv
lver
er an
angl
gle
e
(measure the current)
(measure the current)
•• Ch
Chec
eck
k
re
resi
sist
stan
ance
ce
of
of
th
the
e
thermistor circuit
thermistor circuit
0105
0105
AC voltag
AC voltage in the
e in the
intermediate circuit is too
intermediate circuit is too
low or too high.
low or too high.
Emergency stop.
Emergency stop.
Prevents new drive before
Prevents new drive before
the fault is
the fault is corrected.
corrected.
•• If t
If the
he su
supp
pply
ly vo
volt
ltag
age dr
e drop
ops
s
during drive, decrease the
during drive, decrease the
acceleration
rate
at
acceleration
rate
at
acceleration
(6_21)
acceleration
(6_21)
parameter.
parameter.
•• If t
If thi
his fa
s faul
ult is
t is ac
acti
tive d
ve dur
urin
ing
g
start,
check
the
charging
start,
check
the
charging
circuit, fuses and braking
circuit, fuses and braking
transistor.
transistor.
0106
0106
Inverter not OK
Inverter not OK
Prevents new drive before
Prevents new drive before
the fault is
the fault is corrected.
corrected.
•• Ch
Chec
eck
c
k
con
onne
nect
ctio
ions
ns
of
of
tachometer and thermal switch
tachometer and thermal switch
(XM2).
(XM2).
•• T
Th
he
e v
va
allu
ue
e ffo
orr
Tacho fault
Tacho fault
counter (6_35)
counter (6_35)
parameter may
parameter may
be too sensitive. Turn the
be too sensitive. Turn the
elevator to RDF (machine
elevator to RDF (machine
room
inspection
in
North
room
inspection
in
North
America)
America) and
and back
back to
to Normal
Normal
to reset the tacho fault counter.
to reset the tacho fault counter.
•• If L
If LBR L
BR LED d
ED doe
oes no
s not li
t ligh
ght, r
t, ref
efer
er
to AS-11.65.008 and circuit
to AS-11.65.008 and circuit
diagrams.
diagrams.
•• If
If LB
LBR l
R lig
ight
hts b
s but
ut LB
LBE i
E is n
s not
ot
activated
at
start,
check
activated
at
start,
check
(6_38).
(6_38).
•• If M
If MLB
LB is '
is 'sh
shut
utdo
down
wn',
', ch
chec
eck
k
voltage in the supply and X10/
voltage in the supply and X10/
16 in MLB (+24V).
16 in MLB (+24V).
•• R
Re
em
mo
ov
ve
e tth
he
e U
U
REF2
REF2
jumper.
jumper.
0107
0107
LWD adjustment value out
LWD adjustment value out
of scale.
of scale.
Elevator controller prevents
Elevator controller prevents
the drive. (Drive allows
the drive. (Drive allows
driving)
driving)
•• Ch
Chec
eck th
k the L
e LWD
WD me
mech
chan
anic
ical
al
adjustment and settings of the
adjustment and settings of the
load values.
load values.
•• Ch
Chec
eck t
k the
he lo
load
ad in
in ca
carr..
F
Fa
au
ulltt
S
Sy
ym
mp
ptto
om
ms
s
o
of
f
ffa
au
ulltt
A
Ac
cttiio
on
n
Содержание V3F18
Страница 5: ......