| Operating Instructions
IRL
Operating Instructions|
IRL
If this is not the case, fill the water basin with distilled water
to the “MAX” mark.
If none of the steps as mentioned above restores the unit ...
Unplug the transformer.
Take the mist generator out of the water basin.
Remove the splash protector from the mist generator.
Unscrew the holder with the bronze coloured ceramic mem-
brane on the top of the mist generator using the enclosed
special tool.
Remove the ceramic membrane from the mist generator
and clean it with a damp cloth.
Put the membrane back into the mist generator and fasten
the holder with the enclosed special tool.
Replace the splash protector.
Place the mist generator to its original position in the water
basin.
Insert the mains plug of the transformer in the socket. The
natural-stone fountain is ready for operation again.