background image

This option allows you to use the standard default mode where the controller runs lights at 

night in a “Street lamp” mode, based on light falling on the panel or to power auxiliary 

items at all times, regardless of it being day or night.

1F0 Will disable the timers and always power the load

1F3-1F9 will run the lamps for the time specified, with a range of 3 to 9 hours.

Press and hold K2 until the voltage is able to be set.

Press K2 multiple times until [1F3] appears in the display and press K1 to change this to a 

longer duration, or set to “1F0” to have the load always output power during the day unless 

overloaded, or the battery voltage drops below the cut-off.

IMPORTANT:

Remember to select 9F using K2 and then press K1 to save the setting and reboot the 

controller. The following will appear in th

Modes

Factory Defaults

U00 Voltage auto detect
U12 12V Battery
U24 24V Battery
P NOT FUNCTIONAL
1H NOT FUNCTIONAL
2H NOT FUNCTIONAL
3H NOT FUNCTIONAL
4H NOT FUNCTIONAL
1F0 Load always on
1F3 Load comes on for 3 hours
1F4 Load comes on for 4 hours
1F5 Load comes on for 5 hours
1F6 Load comes on for 6 hours
1F7 Load comes on for 7 hours
1F8 Load comes on for 8 hours
1F9 Load comes on for 9 hours
2F NOT FUNCTIONAL
7F Reset controller to factory settings
9F SAVE changed settings and reset controller

U00 Voltage auto detect

1F3 Load comes on for 3 hours

5

Programming Method

Содержание KDSLR160PNLA

Страница 1: ...ndle and Safety Fasteners The panels are fitted with a heavy duty handle allowing for the easy handling and removal from the protective carry bag Two clip type safety fasteners lock the panel securely...

Страница 2: ...cable from left solar panel to controller 10 Connection cable from right solar panel to controller Product Specifications Solar Panel Type Mono Crystalline MAX Power 2 x 80W Open Circuit Voltage 21 96...

Страница 3: ...ntime after dusk or Always on mode 8 2F_ Fixed at 0 and cannot be changed 9 8F_ Factory test mode 10 9F Save changed user settings and reboot controller Safety Precautions 1 Read and understand this i...

Страница 4: ...can damage such items and result in severe burns 15 Keep the solar panel away from water acids or alkalis 16 Keep the surface of the solar panels clean from dust by cleaning it with a soft dry cloth...

Страница 5: ...he day unless overloaded or the battery voltage drops below the cut off IMPORTANT Remember to select 9F using K2 and then press K1 to save the setting and reboot the controller The following will appe...

Страница 6: ...nces As a general rule the user should establish the amps required to run the appliances then multiply them by the expected module voltage Power Calculations Amp Hours Ah Current amps x Working Time h...

Страница 7: ...tery all the way down to zero during the charge cycle For the example given at least 30 should be left in the battery We will need at least 30 51Ah 0 7 43 6Ah battery for each days use If the battery...

Отзывы: