FOREWORD
PUSH-PULL COUPLER
WA500-6
00-29
Type 2
00
Disconnection
00
1.
Hold the mouthpiece of the tightening portion and push body (2) in
straight until sliding prevention ring (1) contacts contact
surface (
a
) of the hexagonal portion at the male end.
2.
Hold in the condition in Step 1 and turn the lever (4) to the right
(clockwise).
3.
Hold in the condition in Steps 1 and 2 and pull out the whole
body (2) to disconnect it.
Connection
00
•
Hold the mouthpiece of the tightening portion and push body (2) in
straight until sliding prevention ring (1) contacts surface
a
of the
hexagonal portion at the male end to connect the body.