PRECAUTIONS FOR MAINTENANCE
Do not perform any inspection and maintenance operation that are not found in this manual.
CHECK SERVICE METER READING
Check the service meter reading every day to see if the maintenance time has come for any necessary mainte-
nance item to be performed.
KOMATSU GENUINE REPLACEMENT PARTS
Komatsu recommends using Komatsu genuine parts specified in Parts Book as replacement parts.
KOMATSU GENUINE LUBRICANTS
For lubrication of the machine, Komatsu recommends using Komatsu genuine lubricants. Moreover use oil of
the specified viscosity according to the ambient temperature.
ALWAYS USE CLEAN WASHER FLUID
Use automobile window washer fluid, and be careful not to let any dirt get into it.
FRESH AND CLEAN LUBRICANTS
Use clean oil and grease. Also, keep the containers of the oil and grease clean. Keep foreign materials away
from oil and grease.
CHECK DRAINED OIL AND USED FILTER
At the replacement of the filters when oil is changed, check the old oil and filters for metal particles and foreign
materials. If large quantity of metal particles or foreign materials are found, always report to the person in
charge, and perform suitable action.
PRECAUTIONS FOR REFILLING OIL OR FUEL
If your machine is equipped with a strainer, do not remove it while filling oil or fuel.
PRECAUTIONS FOR ADDING DEF
Do not remove the strainer while adding DEF.
WELDING INSTRUCTIONS
• When conducting weld repair, turn the starting switch to OFF position and, after confirming that the system
operating lamp is turned off, set the battery disconnect switch key to OFF position and pull it out.
• Do not apply a voltage higher than 200 V continuously.
• Connect grounding cable within 1 m of the area to be welded. If grounding cable is connected near instru-
ments, connectors, etc., the instruments may malfunction.
• Prevent seals, bearings or bushings from entering the space between the weld zone and grounding point.
Seals and the like can cause damage to the nearby parts by catching fire from sparks.
• Do not use the area around the work equipment pins or the hydraulic cylinders as the grounding point.
Sparks generated there can damage the plated portion.
DO NOT DROP THINGS INSIDE MACHINE
• When opening the inspection windows or the oil filler port of the tank to perform inspection, be careful not to
drop nuts, bolts, or tools inside the machine.
If such things are dropped inside the machine, it may cause damage and/or malfunction of the machine,
and will lead to failure. If anything drops, be sure to take it out.
• Do not put unnecessary things in your pockets. Carry only things which are necessary for inspection.
PRECAUTIONS FOR KDPF
When performing inspection and maintenance during or just after regeneration, take care of the high tempera-
ture parts.
Even after the engine stops the parts around KDPF may be at high temperature.
PRECAUTIONS FOR MAINTENANCE
MAINTENANCE
4-2
Содержание H75051
Страница 2: ... ...
Страница 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Страница 66: ......
Страница 67: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 74: ...Outside of cab 1 Slow blow fuse 2 Frame lock bar GENERAL VIEW OPERATION 3 8 ...
Страница 158: ...SWITCHES g0032100 1 ECSS switch 2 Front working lamp switch EXPLANATION OF COMPONENTS OPERATION 3 92 ...
Страница 289: ...Securing position Fixing angle A 69 B 59 C 33 D 46 Expected trailer width E 2990 mm OPERATION TRANSPORTATION 3 223 ...
Страница 310: ......
Страница 311: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 396: ......
Страница 397: ...SPECIFICATIONS 5 1 ...
Страница 399: ... 1 Value when bucket dump angle is 45 B I A G E H F D C 9 J W0 1 4 5 6 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Страница 400: ......
Страница 424: ......
Страница 425: ...REPLACEMENT PARTS 7 1 ...
Страница 440: ...WA270 8 WHEEL LOADER Form No VENAM31500 2016 KOMATSU Hanomag GmbH All Rights Reserved Printed in Europe 12 2016 ...