METHOD FOR STARTING ENGINE
k
k
WARNING
Check both of normal machine and failed machine that the lock lever is set to LOCK position (the pilot
lamp in the switch lights up). Check also that all the control levers are in NEUTRAL position.
1.
Make sure the clips are firmly connected to the battery terminals.
2.
Start the engine of the normal machine and run it at high idle (max. speed).
3.
Turn the starting switch of the failed machine to START position and start the engine.
If the engine does not start, try it again after 2 minutes or more.
PROCEDURE FOR DISCONNECTING JUMPER CABLES
After the engine has started, disconnect the jumper cables in the reverse of the order in which they were con-
nected.
1.
Remove the clip of jumper cable (B) from engine block (E)
on the failed machine.
2.
Remove the clip of jumper cable (B) from the negative (-)
terminal of battery (D) on the normal machine.
3.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (D) on the normal machine.
4.
Remove the clip of jumper cable (A) from the positive (+)
terminal of battery (C) on the failed machine.
OTHER TROUBLE
PHENOMENA AND ACTIONS FOR ELECTRICAL SYSTEM
• For the remedies indicated with (*) in the remedy column, always contact your Komatsu distributor.
• In cases of problems or causes which are not listed below, ask your Komatsu distributor for repairs.
Problem
Main causes
Remedy
Lamp does not glow brightly even
when the engine runs at high
speeds.
Defective wiring
Check and repair loose terminals,
open circuit. (*)
Defective adjustment of belt tension
Check alternator belt tension. See
"EVERY 1000 HOURS MAINTE-
NANCE".
Lamp flickers while engine is run-
ning.
Defective wiring
Check and repair loose terminal or
wire breakage, replace battery. (*)
Defective adjustment of belt tension
Check alternator belt tension. See
"EVERY 1000 HOURS MAINTE-
NANCE".
Unusual noise is generated from al-
ternator.
Defective alternator
Replace. (*)
Battery charge level caution lamp
lights up while engine is running.
Defective alternator
Replace. (*)
Defective wiring
Check, repair. (*)
Defective adjustment of belt tension
Check alternator belt tension. See
"EVERY 1000 HOURS MAINTE-
NANCE".
TROUBLES AND ACTIONS
OPERATION
3-238
Содержание H75051
Страница 2: ... ...
Страница 27: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Страница 66: ......
Страница 67: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 74: ...Outside of cab 1 Slow blow fuse 2 Frame lock bar GENERAL VIEW OPERATION 3 8 ...
Страница 158: ...SWITCHES g0032100 1 ECSS switch 2 Front working lamp switch EXPLANATION OF COMPONENTS OPERATION 3 92 ...
Страница 289: ...Securing position Fixing angle A 69 B 59 C 33 D 46 Expected trailer width E 2990 mm OPERATION TRANSPORTATION 3 223 ...
Страница 310: ......
Страница 311: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 396: ......
Страница 397: ...SPECIFICATIONS 5 1 ...
Страница 399: ... 1 Value when bucket dump angle is 45 B I A G E H F D C 9 J W0 1 4 5 6 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Страница 400: ......
Страница 424: ......
Страница 425: ...REPLACEMENT PARTS 7 1 ...
Страница 440: ...WA270 8 WHEEL LOADER Form No VENAM31500 2016 KOMATSU Hanomag GmbH All Rights Reserved Printed in Europe 12 2016 ...