FRONT PANEL:

PR1÷PR8 led for each single program (socket):

-

If on, it indicates the program in use.

-

If flashing, it indicates the program to be selected (sequence mode and ext box enabled )

STOP MOTOR led: if on it indicates the motor is not enabled.

ESC-OK-RESET buttons are enabled through line 4 in the option menu (OK-ESC) by choosing one of the
following options:

INT = Only the buttons on the front panel of the control unit are operational
EXT  = Only the buttons of the socket tray are operational (for the below mentioned
options)
INT- EXT  = Both the socket tray and control unit buttons are operational.

RESET button:

It resets the program or sequence (line 5 in the option menu)

-

PR = it resets one single program.

-

SEQ = it resets the whole sequence (enabled only if the sequence mode is on).

ESC button:

Enabled according to the program (line 17 in the program menu)

-

If ON   = the ESC button must be pressed in order to reset the error signal.

-

If OFF = the error is automatically reset.

OK button:

Enabled according to line 16 in the program menu.

PROGRAM:

-

If ON  = the program automatically resets.

-

If OFF = the button must be pressed at the end of the program.

SEQUENCE: (Line 5 in the program menu).

-

If ON  = the sequence automatically resets.

-

If OFF = the OK button must be pressed at the end of the sequence.