EB-20X Installation & Service Manual | 

Wiring

 

 

 

 

14 

Kollmorgen | kdn.kollmorgen.com | September 2020 

Notes for Typical Motor Wiring 

1.  The motor thermostat is an automatic resetting device and should be connected into a 

latched (lock-out) power down type circuit. 

2.  Thermostat to be wired with twisted pair. 
3.  Energize the brake before switching the motor on and while it is in operation. For proper 

operation, use an electrical interlock circuit to ensure that the brake is not engaged while the 

motor is energized. 

Model 

Holding VDC 

Holding ADC 

EB-20X-X-XX-B2 

90 

0.09 

EB-20X-X-XX-B3 

24 

0.52 

 

4.  Application resolver leads will exit at a different location from system resolver leads. 

2. 5  GROUNDING  

Ground the motor at the amplifier motor terminal block or at the main ground point. Connect 

shielded cables at one end only. Butt the other end. 

2. 6  INPUTS 

The drive-up contact closure (internal) is provided at pins 10 and 20. When this internal contact is 

closed, it indicates to the outside world (software) that the typical amplifier is ready to operate. 

When open, it is an indication that it is in the inhibit mode. The contact is rated at 115 VAC at 2 

amps. 

 

The motor is provided with two, normally-closed thermostat reset 

devices connected in series. They are auto-resetting devices intended 

to shut off power from the amplifier to limit the surface temperature of 

the motor and prevent ignition in hazardous atmospheres. 

The remote inhibit disables the amplifier without removing the main power. When a contact is 

closed between pins (2 and 15) D common, the amplifier is placed in drive-up or ready-to-operate 

mode. Opening the contact places the amplifier in the inhibit, or non-operable mode. These pins 

(2 and 15) are connected through the latched power down circuit to the motor thermostat (see B-

84470). The motor thermostat is an automatic resetting device that is used to shut the power 

down from the controller should an over-temperature condition occur in the motor windings. 

Connect the thermostat to a latched (locked out) power-down type circuit that requires a manual 

reset. This prevents inadvertent restart of the motor when it cools down below the thermostats set 

value. 

2. 7  PRELIMINARY CHECKS 

Once the typical amplifier system has been installed and wired in, use the following steps to 

ensure proper operation before the main power is applied. 

Содержание EB-8902

Страница 1: ...less Motor Amplifier EB 20X Series Motors Installation and Service Manual Edition September 2020 Revision B Part Number EB 8902 Original Document For safe and proper use follow these instructions Keep...

Страница 2: ...t to no more that 300 of rated current for a maximum period of 8 seconds Do not install the amplifier in a hazardous classified location unless the amplifier is listed for such location The motor is U...

Страница 3: ...7 1 CHECK AC INPUT VOLTAGE 15 2 7 2 CHECK DC OUTPUT VOLTAGE 15 2 7 3 ZERO SYSTEM RESOLVER 15 2 8 3 PHASE POWER TRANS 16 3 MOTOR DATA PACKAGE 18 3 1 MODEL NUMBER 18 3 2 EB 20X 19 3 2 1 EB 20X 11 19 3 3...

Страница 4: ...d with Kollmorgen s high performance permanent magnet brushless motors An unregulated 300 VDC bus derived from full wave rectification of a 3 phase 230 AC line by the power supply unit is used to powe...

Страница 5: ...inrush current remains limited to less than 1000 amps 115 VAC 1 phase control power Output Power Power Supply DC Bus 325 VDC nominal no load Amplifier at rated load 230 VRMS L L Nominal 10 Continuous...

Страница 6: ...s and that it is not offset to one side To access the control terminal strips to wire the typical amplifier review the wiring diagrams and 1 Wire the typical amplifier control terminal strips per the...

Страница 7: ...2 1 1 OUTLINE DIMENSIONS INDUSTR IAL DRIVES BOS4 C 1 C 3 C 2 M o M a BU S BU S Mc GN D CURRENT LIMIT COMMAND SCALE BALANCE CONTROL VOLTS ENABLED DRIVE READY FOLDBACK OVERTEMP OUTPUT FAULT STABILITY 0...

Страница 8: ...CATORS DRIVE ADJUSTMENTS POWER STAGE INDUSTRIAL DRIVES BOS4 C1 C3 C2 Mo Ma BUS BUS Mc GND CHASSIS GND DRIVE ADJUSTMENTS DRIVE INDICATORS CUSTOMER I O CONN RESOLVER CONN LOGIC SUPPLY CONN BUS MOTOR CON...

Страница 9: ...2 2 TYPICAL POWER SUPPLY 2 2 1 OUTLINE DIMENSIONS INDUSTRI AL DRIVES C 1 C 2 Lb La BUS BUS Lc GND REGEN OVERLOAD BLOWN FUSE 0 00 254 00 279 44 0 00 28 00 48 00 0 00 7 50 15 50 R5 00 6 50 DIA 0 00 18 0...

Страница 10: ...TROL VOLTAGE OUTPUT REGEN OVERLOAD BLOWN FUSE MAIN D C BUS OUTPUT MAIN INPUT POWER REGEN LED OVERLOAD LED BLOWN REGEN FUSE LED REGEN OVERLOAD BLOWN FUSE 2 2 3 SIDE VIEW REGENERATIVE LOAD RESISTORS REG...

Страница 11: ...5 VAC CONTROL VOLTAGE SEE NOTE 1 POWER BUS TO ADDITIONAL AXIS MODULES GND GND Mc Mb Ma BUS BUS TYPICAL AMPLIFIER TO MOTOR ON SHEET 2 18 AWG MIN FOR 3 AND 6 AMP UNIT 14 AWG MIN FOR 10 AMP UNIT 12 AWG M...

Страница 12: ...4S or SS20947SF for 16 14 AWG wire and XSS20836 or SS20832F for 12 10 AWG wire 4 Wire gauge is dependent on application For total axis currents less than 9 amps use 16 AWG For total axis currents grea...

Страница 13: ...ACK YELLOW BLUE YEL WHT RED WHT A B C D E F SIN HI SIN LO COS LO COS HI REF HI REF LO I O OPTO 22 LATCHED POWER DOWN RELAY RED BLACK YELLOW BLUE YEL WHT RED WHT A B C D E F SIN HI SIN LO COS LO COS HI...

Страница 14: ...hat it is in the inhibit mode The contact is rated at 115 VAC at 2 amps The motor is provided with two normally closed thermostat reset devices connected in series They are auto resetting devices inte...

Страница 15: ...tion transformer 2 7 2 CHECK DC OUTPUT VOLTAGE Do not apply the 115 VAC Apply power to the large 3 phase transformer only With a DC voltmeter monitor the 325 VDC bus bars of the power supply and ampli...

Страница 16: ...EB 20X Installation Service Manual Wiring 16 Kollmorgen kdn kollmorgen com September 2020 2 8 3 PHASE POWER TRANS...

Страница 17: ...EB 20X Installation Service Manual Wiring Kollmorgen kdn kollmorgen com September 2020 17...

Страница 18: ...locations Neodymium Iron Boron magnets Aluminum end bells Frameless shaft mounted resolver Rugged construction 3 1 MODEL NUMBER EB 0x A is the winding designation is the stack length designation EB i...

Страница 19: ...71 in 0 12 0 007 80 00 mm 3 150 in 14 00 mm 0 551 in 13 0 mm 0 51 in 97 0 mm 3 82 in SQUARE MOTOR RESOLVER THERMOSTAT LEADS LEAD EXIT 3 4 14 NPT FOR CONDUIT SIX 6 FULL THREADS MIN A 0 08 TIR 0 003 A 0...

Страница 20: ...m m rad sec2 48681 48417 48945 Horsepower Rated HP rtd HP 4 4 7 7 6 1 Speed Rated N rtd rpm 2000 4000 3000 Torque Rated T rtd lb ft 11 6 10 1 10 7 N m 15 7 13 7 14 5 Volts line to line Rated V rtd VRM...

Страница 21: ...lb 37 kg f 16 8 Static Friction TF lb ft 0 360 N m 0 490 Thermal Time Constant Peak TCTP Minutes 12 Viscous Damping Z Source F1 lb ft krpm 0 053 N m krpm 0 072 If brush type tach is used these parame...

Страница 22: ...RMANCE CURVES 3 3 2 1 EB 202 A PC 26721 Do not operate this motor outside the parameters shown on this performance curve Motor EB 202 A Drive BDS4 230 3 Test T3 1339 2800 2400 2000 1600 1200 800 400 0...

Страница 23: ...26722 Do not operate this motor outside the parameters shown on this performance curve Motor EB 202 B Drive BDS4 230 3 Test Calculated 0 2 4 6 CONTINUOUS DUTY ZONE Trated Nmax Nrated 1000 TORQUE lb f...

Страница 24: ...B 202 C PC 26723 Do not operate this motor outside the parameters shown on this performance curve Motor EB 202 C Drive BDS4 230 6 Test Calculated 0 0 0 5 1 1 5 2 2 5 1000 CONTINUOUS DUTY ZONE Trated T...

Страница 25: ...m rad sec2 73961 81020 70196 Horsepower Rated HP rtd HP 1 20 2 30 3 70 Speed Rated N rtd rpm 1900 3600 6200 Torque Rated T rtd lb ft 3 20 3 41 3 13 N m 4 34 4 62 4 25 Volts line to line Rated V rtd V...

Страница 26: ...t lb 18 kg f 8 2 Static Friction TF lb ft 0 005 N m 0 007 Thermal Time Constant Peak TCTP Minutes 20 Viscous Damping Z Source F1 lb ft krpm 0 005 N m krpm 0 007 If brush type tach is used these parame...

Страница 27: ...VES 3 4 2 1 EB 204 A PC 26724 Do not operate this motor outside the parameters shown on this performance curve Motor EB 204 A Drive BDS4 230 3 Test Calculated 0 1 2 3 CONTINUOUS DUTY ZONE Trated Tc IN...

Страница 28: ...2 2 EB 204 B PC 26725 Do not operate this motor outside the parameters shown on this performance curve Motor EB 204 B Drive BDS4 230 6 Test T3 1393 3500 4000 3000 2500 2000 1500 1000 500 0 0 1 2 3 4 N...

Страница 29: ...4 2 3 EB 204 C PC 26719 Do not operate this motor outside the parameters shown on this performance curve Motor EB 204 C Drive BDS4 230 10 Test T3 1396 7000 6000 5000 4000 3000 2000 1000 0 0 1 2 3 4 5...

Страница 30: ...om m rad sec2 75715 75715 67674 Horsepower Rated HP rtd HP 1 20 2 50 3 80 Speed Rated N rtd rpm 1400 2800 4900 Torque Rated T rtd lb ft 4 5 4 6 4 06 N m 6 1 6 24 5 5 Volts line to line Rated V rtd VRM...

Страница 31: ...t lb 21 kg f 9 5 Static Friction TF lb ft 0 005 N m 0 007 Thermal Time Constant Peak TCTP Minutes 22 Viscous Damping Z Source F1 lb ft krpm 0 008 N m krpm 0 011 If brush type tach is used these parame...

Страница 32: ...URVES 3 5 2 1 EB 206 A PC 26726 Do not operate this motor outside the parameters shown on this performance curve Motor EB 206 A Drive BDS4 230 3 Test Calculated 0 0 800 CONTINUOUS DUTY ZONE Trated Tc...

Страница 33: ...3 3 5 2 2 EB 206 B PC 26460 Do not operate this motor outside the parameters shown on this performance curve Motor EB 206 B Drive BDS4 230 6 Test T3 1394 0 0 2000 CONTINUOUS DUTY ZONE Trated Tc INTERM...

Страница 34: ...06 C PC 26720 Do not operate this motor outside the parameters shown on this performance curve Motor EB 206 C Drive BDS4 230 10 Test T3 1397 TORQUE lb ft 3 8 HP INTERMITTENT DUTY ZONE Tp SPEED rpm 6 7...

Страница 35: ...7 The EB 206 C is illustrated at 1500 rpm 4 4 lb ft 3 7 INTERMITTENT DUTY OPERATION If a motor operates intermittently it is not necessary that the peak load torques fall within the motor s continuous...

Страница 36: ...he above equation yields EQ 2 TOFF TCTP 1n 1 1 e t TCTP TOUT ON 2 tON TC 2 Thus for a specific output torque and a given ON time the required OFF time is known This OFF time is required so that the mo...

Страница 37: ...erating intermittently at 4900 rpm with a torque of 6 6 lb ft FIND a maximum ON time without exceeding ultimate temperature b the required OFF time for an ON time of 4 seconds GIVEN TOUT 6 6 lb ft Fro...

Страница 38: ...TC 4 1 lb ft at 2500 rpm From Specifications CD 26718 TCTP 22 min a Using EQ5 and the values above tMAX 5 6 min b Using EQ2 and an On time of 4 seconds an OFF time is tOFF 13 7 seconds Example 3 The...

Страница 39: ...R SPECIFICATIONS Amplifier Specifications Input Power to Amplifier 230 VRMS L L 30 15 Isolation Transformer Not Required 115 VAC 10 Control Power 10 15 Output Power to Motor Power Supply DC Bus 325 VD...

Страница 40: ...5 37 Example 1 38 Example 2 39 Example 3 39 Grounding 15 Input Power 6 Intermittent Duty Operation 36 Model Number 19 motor 5 Motor data package 19 Outline Dimensions 10 Outline Dimensions 8 Output P...

Страница 41: ...EB 20X Installation Service Manual Index Kollmorgen kdn kollmorgen com September 2020 41 voltage line A C 36 Wiring input power 6 National Code 6 typical motor 14 typical power supply 11...

Страница 42: ...work for product support Ask the community questions search the knowledge base for answers get downloads and suggest improvements North America Kollmorgen 201 West Rock Road Radford VA 24141 USA Web w...

Отзывы: