5

Graphic Operator Terminal / 

CONSIDERATIONS AND SAFETY PRECAUTIONS

 

 
 

 

The supplier neither guarantees that the graphic operator terminal is suitable for your 
particular application, nor assumes responsibility for your product design, installation or 
operation. 

1.3 During 

Installation 

 

The graphic operator terminal is designed for stationary installation on a plane surface, where 
the following conditions are fulfilled: 

– 

no high explosive risks 

– 

no strong magnetic fields 

– 

no direct sunlight 

– 

no large, sudden temperature changes 

 

Install the product according to the accompanying installation instructions. 

 

Ground the product according to the accompanying installation instructions. 

 

Only qualified personnel may install the graphic operator terminal. 

 

Separate the high voltage, signal and supply cables. 

 

Make sure that the voltage and polarity of the power source is correct before connecting the 
product to the power outlet. 

 

Peripheral equipment must be appropriate for the application and location. 

1.4 During 

Use 

 

Keep the graphic operator terminal clean. 

 

Emergency stop and other safety functions may not be controlled from the graphic operator 
terminal. 

 

Do not use too much force or sharp objects when touching the touch screen etc. 

1.5 Service 

and 

Maintenance 

 

Only qualified personnel should carry out repairs. 

 

The agreed warranty applies. 

 

Before carrying out any cleaning or maintenance operations, disconnect the equipment from 
the electrical supply. 

 

Clean the display and surrounding front cover with a soft cloth and mild detergent. 

 

Replacing the battery incorrectly may result in explosion. Only use batteries recommended by 
the supplier

 

Содержание AKI-CDT-MOD-06T

Страница 1: ...rminal Installation Manual Revision 1 1 August 2011 AKI CDT MOD 06T 5 7 Touchscreen HMI Keep all manuals as a product component during the life span of the product Pass all manuals to future users own...

Страница 2: ...may not be disclosed to third parties translated copied or duplicated in any form in whole or in part without the express written permission of Kollmorgen Registered Trademarks Kollmorgen is a regist...

Страница 3: ...al Resistance 4 1 Metal Casing 13 4 2 Touch Screen and Overlay 14 4 3 Autotex F157 F207 14 4 4 Touch Screen Surface 15 4 5 Touch Screen Protector 15 5 Operator Terminal Diagrams 5 1 Communication Port...

Страница 4: ...ns carefully Check the delivery for transportation damage If damage is found notify the supplier as soon as possible Do not use the graphic operator terminal in an environment with high explosive haza...

Страница 5: ...graphic operator terminal Separate the high voltage signal and supply cables Make sure that the voltage and polarity of the power source is correct before connecting the product to the power outlet Pe...

Страница 6: ...Dismantling and Scrapping The graphic operator terminal or parts thereof shall be recycled according to local regulations The following components contain substances that might be hazardous to health...

Страница 7: ...0 3 inch Space requirements when installing the graphic operator terminal CAUTION The openings on the enclosure are for air convection Do not cover these openings 2 2 Installation Process 1 Unpack an...

Страница 8: ...controller system have the same electrical grounding reference voltage level otherwise errors in communication may occur B Use an M5 screw and a grounding conductor as short as possible with a cross s...

Страница 9: ...mode switches DIP switches located on the rear side of the operator terminal All mode switches must be in OFF position during graphic operator terminal use The mode switches should not be touched unl...

Страница 10: ...ing the file system in the operator panel are deleted when upgrading with Image Loader 1000 Service Menu mode the service menu for the system program is shown Allows the user to set IP configuration e...

Страница 11: ...oated aluminum Weight 0 9 kg Serial port RS422 RS485 25 pin D sub contact chassis mounted female with standard locking screws 4 40 UNC Serial port RS232C 9 pin D sub contact male with standard locking...

Страница 12: ...the requirements for class II power supplies Ambient temperature Vertical installation 0 to 50 C Horizontal installation 0 to 40 C Storage temperature 20 to 70 C Relative humidity 5 85 non condensed...

Страница 13: ...3 Tap water The powder paint shows limited resistance to the following chemicals at room temperature Chemicals Butanol Nitric acid 3 Hydrochloric acid 5 Nitric acid 10 Isopropyl alcohol Phosphoric ac...

Страница 14: ...50 Gumption1 SBP 60 951 Ariel powder in solution1 Hydrochloric acid 36 Sulfuric acid 10 Bleach1 Linseed oil Tomato ketchup Castor oil Methanol Tricjloroacetic acid 50 Caustic soda 40 1 Nitric acid 10...

Страница 15: ...e 5 hours 4 5 Touch Screen Protector It is recommended to use the Touch Screen Protector film that can be ordered from Kollmorgen Solvent Resistance The Touch Screen Protector film withstands exposure...

Страница 16: ...Graphic Operator Terminal OPERATOR TERMINAL DIAGRAMS 5 OPERATOR TERMINAL DIAGRAMS This chapter provides the operator terminal diagrams 5 1 Communication Port Diagrams 16...

Страница 17: ...Graphic Operator Terminal OPERATOR TERMINAL DIAGRAMS 17 5 2 Outline Diagrams...

Страница 18: ...inet Connect a 2 5 mm2 wire between the graphic operator terminal s quick connect plinth and the terminal chassis Connect a 6 or 4 mm2 wire or grounding braid between the terminal s chassis and the cl...

Страница 19: ...assis via a capacitor The graphic operator terminal s Ethernet shield is directly connected to the chassis Check whether the other Ethernet unit has its shield directly grounded or grounded via a capa...

Страница 20: ...ations for the relevant bus standard Use shielded cabling for Ethernet preferably with foil braided shield D sub covers should be shielded and the shield should be connected to the cover 360 where the...

Страница 21: ...vided in the specifications The ambient temperature refers to the temperature in the device cabinet which cools the terminal s electronics In most cases the ambient temperature for the graphic operato...

Страница 22: ...nuous use If a thermostat is installed the fan only needs to come on when needed Large graphic terminals draw only one fifth of the current when the background lighting is off The loss effect drops fr...

Страница 23: ...ds Connect 0 V on the 24 V feed to the ground This offers three advantages Safety is increased The 24 V feed will not be live in the event of a faulty connection or short circuit between 0 V 24 V and...

Страница 24: ...The pair capacitance may not exceed 52 5 pF m and area at least 0 25 mm2 AWG 24 if you want to use the maximum transfer distance and maximum transfer speed 0 V the reference voltage for communication...

Страница 25: ...AKI CDT MOD 06T 5 7 Touchscreen HMI A 1 AKI CDT MOD 06T 5 7 Front View 1 152 mm 202 mm A 2 AKI CDT MOD 06T 5 7 Front View 2 180 1 7 09 0 04 12 0 47 mm 10 0 39 mm 130 1 5 12 0 04 10 5 0 41 mm 11 5 0 4...

Страница 26: ...perator Terminal APPENDIX A A 3 AKI CDT MOD 06T 5 7 Bottom View COM2 RS232 COM1 RS422 485 24VDC A 4 AKI CDT MOD 06T 5 7 Side View max mmmaterialthickness 7 5 Battery DIP switch USB host Ethernet 6 mm...

Страница 27: ...Graphic Operator Terminal APPENDIX A A 5 AKI CDT MOD 06T 5 7 Back View 178 63mm 12 44mm 128 73 mm 10 94mm 12 34 mm 10 94 mm 27...

Страница 28: ...ugh solutions that are unmatched in performance reliability and ease of use giving machine builders an irrefutable marketplace advantage For assistance with your application needs contact us at 540 63...

Отзывы: