7.14.9 Technical data and pinout local STO
The local STO input is not compatible with IEC 61131-2.
STO-Enable input
Input does not match IEC61131-2
ON: 18 VDC to 30 VDC, 100 mA
OFF: 0 VDC to 12 VDC, < 50 mA
Galvanic isolation for 250 VDC
Tolerated OSSD pulse duration 0.3 ms
STO-Status outputs
As per IEC61131-2 type 1
Max. 30 VDC, 100 mA
Galvanic isolation for 250 VDC
24 VDC Power supply
PELV acc. to EN 60204-1
Output 24 VDC +/-10%
Wiring diagram local STO-Enable
M12, A-coded
X6 Pinout
Description
1
STO-
2
STO-Enable -
3
n.c.
4
n.c.
Wiring diagram local STO-Status
M12, A-coded
X3 Pinout
Description
1,2
see (
3
STO Status -
4
STO
5,6,7,8
see (
AKD-N Installation | 7 Technical description and data
Kollmorgen | kdn.kollmorgen.com | February 2018
45