TECHNICAL HANDBOOK
INDUSTRIAL ROLLER SHUTTER_(RSM)
KOLLIAS Ltd.
Page 35/46
D.Z. –Ver.1
st
– 08/12/17
Address:
3rd km. National Highway Katerini - Thessaloniki
Katerini
Postal address:
P.O. Box : 91
60100, Katerini
Tel.:
+30 23510 36036
Fax:
+30 23510 45630
Web: www.kolliasdoors.com
using a tool. Then we lift the roller shutter and lower it again, in order to check that the previous
terminal setting is accurate. If this is not the case, then we proceed with a correction and repeat the
process.
Figure 9
After completing the setting of the lower terminal switch, we begin the procedure for setting the
top position of the roller shutter. By pressing the ASCENT button (BROWN wire) we notice that the rotors
of the terminal board move to the left. Raise the roller shutter to the position where the bottom bar and
the roller shutters slat are located within the guides. In this position we must adjust that the left rotor,
controlling the ascent, presses the corresponding contact. Then we lower the roller shutter and raise it to
check that the previous terminal setting is accurate. If this is not the case, then we proceed with a
correction and repeat the process.
STEP 9: Photocells installation
In the case of devices equipped with photocells, they should be placed at a height of about 50 cm
from the floor. Particular care must be taken to ensure that the height of the photocells is exactly the
same for both vertical guides.
Ascent rotor
Descent rotor
Αscent control contact
Descent control contact
Rotor’s locking bolts