OPERATING  THE  UNIT

W hen using the unit

 When first using the dehumidifier, operate the unit
 continuously 24 hours.

This unit is designed to operate with a working 

O

O

O

O

environment between 5 C/41 F and 35 C/95 F.
If the unit has been switched off and needs to be 
switched on again quickly, allow approximately
three minutes for the correct operation to resume.
Do not connect the dehumidifier to a multiple socket 
outlet, which is also being used for other electrical 
appliances.
Select a suitable location, making sure you have easy 
access to an electrical outlet.
Plug the unit into a  electrical socket-outlet with earth 
connection.
Make sure the Water bucket is correctly fitted otherwise 
the unit will not operate properly.

NOTE:

When the water in the bucket reaches to a certain 

level,please be careful to move the machine to avoid it 
falling down.

 A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed
 storage area, such as a closet, unless there is adequate circulation of air in and out of the area.

Air outlet grille

Air intake
grille

20cm or more

20cm or more

20cm or more

20cm or more

40cm or 
more

Positioning the unit

 Do not use outdoors.
 This dehumidifer is intended for indoor residential 
 applications only. This dehumidifier should not be used
 for commercial or industrial applications.
 Place the dehumidifier on a smooth, level floor strong
 enough to support the unit with a full bucket of water.
 Allow at least 20cm of air space on all sides of the unit
 for good air circulation.
 Place the unit in an area where the temperature will not

O

O

 fall below 5 C(41 F). The coils can become covered with 

O

O

 frost at temperatures below 5 C(41 F), which may reduce
 performance.
 Place the unit away from the clothes dryer, heater or radiator.
 Use the unit to prevent moisture damage anywhere books
 or valuables are stored.
 Use the dehumidifier in a basement to help prevent 
  moisture damage.
 The dehumidifier must be operated in an enclosed
 area to be most effective.
 Close all doors, windows and other outside openings
 to the room.

Removing the collected water

1. Pull out the bucket  a little.

2. Hold both sides of the bucket
    with even strength, and pull it 
    out from the unit.

3. Pour the water out.

There are two ways to remove collected water.

1. Use the bucket

    

When the unit is off,if the bucket is full, the unit 

     will beep 8 times and the Full indicator light will 

     flash, the digital display shows P2.

     When the unit is on,if the bucket is full, the 

     compressor turns off and the fan turns off after 

     30 seconds for drying the water of the condenser, 

     then the unit  will beep 8 times and the Full 

     indicator light will flash, the digital display 

     shows P2.

     Slowly pull out the bucket. Grip the left and 

     right handles securely, and carefully pull out 

     straight so water does not spill. Do not put 

     the tank on the floor because the bottom of 

     the bucket is uneven. Otherwise the bucket 

     will fall and cause the water to spill.

     Throw away the water and replace the bucket. 

     The bucket must  be in place and securely 

     seated for the dehumidifier to operate.

     The machine will re-start when the bucket is 

     restored in its correct position.

NOTES:

    When you remove the bucket, do not touch 

    any parts inside of the unit. Doing so may 

    damage the product. Be sure to push the 

    bucket gently all the way into the unit. 

    Banging the bucket against anything or 

    failing to push it in securely may cause the 

    unit not to operate. 

    When you remove the bucket,if there is some 

    water in the unit you must dry it .

Fig.5

Fig.6

OPERATING  THE  UNIT

Casters(Install at four points on the
bottom of unit)
    

Do not force casters to move over 

    carpet, nor move the unit with water
    in the bucket. (The unit may tip over 
    and spill water.)
NOTE:Casters is optional,some 
            models without.

Содержание KDM-20LES

Страница 1: ...00000251 KPII20180410 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version KDM 20LES DEHUMIDIFIER USER MANUAL ...

Страница 2: ...on and recycling must be performed by a certified technician Fluorinated greenhouse gases are contained in hermetically sealed equipment For 2 Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common ...

Страница 3: ...ic shock Do not take the water buc ket out during operation SAFETY PRECAUTIONS Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit dete...

Страница 4: ...on will also be cancelled Display Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Codes AS Humidity sensor error Unplug the unit and plug it back in If error repeats call for service 5 Timer Pad Press to initiate the ...

Страница 5: ...al room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the door and window To make the best effective dehumidification please first dehydrate the wet clothes Make sure to direct airflow at the wet clothes See Fig A For thick and heavy wet clothes may not get the best effective dehumidification CAUTION Do no...

Страница 6: ...r radiator Use the unit to prevent moisture damage anywhere books or valuables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room Removing the collected water 1 Pull out the bucket a little 2 Hold both sides of the bucket with even str...

Страница 7: ...lle and Case Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock cause the insulation to deteriorate or cause the unit to rust The air intake and outlet grilles get soiled easily so use a vacuum attachment or brush to clean 2 Clean the bucket Every few weeks clean the bucket to prevent growth of mold m...

Страница 8: ... Did not allow enough time to remove the moisture Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes...

Отзывы: