Kolin KDM-20LES Скачать руководство пользователя страница 5

6

7

IDENTIFICATION  OF  PARTS

Power Cord and plug

Drain hose outlet

Air intake grille
 
Air filter (behind the grill)

Front

Rear

Air outlet grille

Caster

Identification of par ts

Fig.2

Fig.3

Water bucket

Control panel

Handle (both sides)

Water level window

1

2

3

4

5

1

2

3

4

NOTE:

 

All the pictures in the manual are 

for explanation purposes only. The actual 
shape of the unit you purchased may be 
slightly different, but the operations and 
functions are the same.
             

5

4

4

5

5

Dryer mode(optional)

The unit can make the MAX dehumidification function 

when it is under the Dryer mode. The fan speed is fixed 

at high fan speed. The humidity level is automatically 

controlled according to the actual room humidity.The unit 

will quit dryer mode after a maximum 10 hours' operation.

NOTE: 

The Dryer mode must be operated in a close room,do not 

open the door and window.

To make the best effective dehumidification ,please first 

dehydrate the wet clothes.

Make sure to direct airflow at the wet clothes (See Fig.A).

For thick and heavy wet clothes may not get the best

effective dehumidification. 

     CAUTION

Do not cover the air outlet of the unit with clothes. It may 

cause excessive heat, fire or failure of unit. 

Do not place the wet clothes on the top of the unit and do

not make the water drop into the unit. It may cause 

electric shock,creepage or failure of unit.

30~50cm 

30~50cm 

Airflow 

Fig.A

Wet clothes

Allow 30~50cm of distance
on the top and right side of
the unit to the wet clothes.

1

2

3

1

2

3

6

Power cord Buckle(Used 
only when storing the unit.)

6

CONTROL  PADS  ON  THE  DEHUMIDIFIER

Содержание KDM-20LES

Страница 1: ...00000251 KPII20180410 The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details Any updates to the manual will be uploaded to the service website please check for the latest version KDM 20LES DEHUMIDIFIER USER MANUAL ...

Страница 2: ...on and recycling must be performed by a certified technician Fluorinated greenhouse gases are contained in hermetically sealed equipment For 2 Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner You ll find many answers to common ...

Страница 3: ...ic shock Do not take the water buc ket out during operation SAFETY PRECAUTIONS Do not cover the intake or exhaust openings with cloths or towels A lack of air flow can lead to overheating and fire Never insert your finger or other foreign objects into grills or openings Take special care to warn children of these dangers Do not use in areas where chemicals are handled This will cause the unit dete...

Страница 4: ...on will also be cancelled Display Shows the set humidity level from 35 to 85 or auto start stop time 0 24 while setting then shows the actual 5 accuracy room humidity level in a range of 30 RH Relative Humidity to 90 RH Relative Humidity Error Codes and Protection Codes AS Humidity sensor error Unplug the unit and plug it back in If error repeats call for service 5 Timer Pad Press to initiate the ...

Страница 5: ...al room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the door and window To make the best effective dehumidification please first dehydrate the wet clothes Make sure to direct airflow at the wet clothes See Fig A For thick and heavy wet clothes may not get the best effective dehumidification CAUTION Do no...

Страница 6: ...r radiator Use the unit to prevent moisture damage anywhere books or valuables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room Removing the collected water 1 Pull out the bucket a little 2 Hold both sides of the bucket with even str...

Страница 7: ...lle and Case Use water and a mild detergent Do not use bleach or abrasives Do not splash water directly onto the main unit Doing so may cause an electrical shock cause the insulation to deteriorate or cause the unit to rust The air intake and outlet grilles get soiled easily so use a vacuum attachment or brush to clean 2 Clean the bucket Every few weeks clean the bucket to prevent growth of mold m...

Страница 8: ... Did not allow enough time to remove the moisture Make sure there are no curtains blinds or furniture blocking the front or back of the dehumidifier The humidity control may not be set low enough Check that all doors windows and other openings are securely closed O O Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room The unit makes...

Отзывы: