background image

 

H

Important Safety Notes:

When using this product, basic safety precautions should always be followed, including 

the following: 

•  Do not use this unit in areas where it may be exposed to water or any other liquids.

•  Only use the power cord supplied with the machine. Plug the power cord into a 

properly grounded wall outlet. Do not remove the ground pin from the power cord. 

Failure to properly ground the machine can result in severe injury or fire.

•  Make certain the unit is installed on a flat surface. Do not operate the machine in 

areas with high temperature, humidity or smoke as these conditions may prevent 

proper operation.

•  Do not start the unit when the rear access panel is open. Ensure no coins are in the 

hopper when the machine is first turned on.

•  When not using the unit for an extended period of time, disconnect the power cord 

from the wall outlet.

•  Unplug the unit from the wall outlet before cleaning. Use a damp cloth or accessories 

such as an  air duster or soft bristle brush.

•  To avoid the risk of electrical shock, do not disassemble this unit. Disassembly will 

expose you to dangerous voltages and other safety risks. Incorrect reassembly can 

cause an electrical shock when the appliance is subsequently used.

•  Take the unit to a qualified technician when service or repair is required. Do not try to 

replace any parts yourself.

This manual contains important information on safety measures and 

operational features of the KCS-2000 coin counter and sorter. Please 

read it carefully before operating your machine and keep it for future 

reference.

While every effort has been made to include all features into this user 

manual, specifications stated may not reflect all the features of the later 

software versions. 

If you have questions about your KCS-2000 and its operation, please 

contact technical support at www.kolibriusa.com/contact/.

CHOKING HAZARD.

SMALL PARTS. 

Not for children under 

3 years old.

DO NOT DISPOSE 

IN TRASH. 

Follow 

appropriate local electronics 

scrap procedures.

WARNING: RISK OF 

ELECTRICAL SHOCK. 

This 

equipment is to be serviced by 

trained personnel only.

WARNING: HAZARDOUS

MOVING PARTS. 

Do not 

place fingers, hair, clothes, 

lanyard... near moving parts.

PROP 65 WARNING. 

This product may contain chemicals known to the State 

of California to cause cancer, or birth defects or other reproductive harm.

https://oehha.ca.gov/

Содержание KCS-2000

Страница 1: ...KCS 2000 Kolibri KCS 2000 Coin Counter Sorter USER MANUAL ...

Страница 2: ...will expose you to dangerous voltages and other safety risks Incorrect reassembly can cause an electrical shock when the appliance is subsequently used Take the unit to a qualified technician when service or repair is required Do not try to replace any parts yourself This manual contains important information on safety measures and operational features of the KCS 2000 coin counter and sorter Pleas...

Страница 3: ..._________________________________ 10 3 MAINTENANCE TROUBLESHOOTING WARRANTY CONTACT INFORMATION 3 1 Maintenance___________________________________________________________________ 13 3 2 Troubleshooting_______________________________________________________________ 15 3 3 Warranty_______________________________________________________________________ 16 3 4 Contact Information______________________...

Страница 4: ...Up to 2 000 coins varies for each currency Coin Tray capacities Batch range 0 500 coins Display 7 digit LED Dimensions 11 18 x 10 24 x 10 83 284 x 260 x 275 mm Weight 8 7 lbs 3 95 kg Counting speed Up to 300 coins min Input power 110 VAC 60 Hz or 220 VAC 50Hz refer to input power label on the rear of this unit Power consumption 45 watts maximum Ambient temperature 0ºC 40ºC 32ºF 104ºF Ambient humid...

Страница 5: ...e power switch located on the rear of the unit The machine will conduct a self check The main display will show 0 when the test has successfully completed 2 2 Counting The KCS 2000 always operates in a batching mode by default To enable simple counting all batch quantities need to be set to zero To set batch quantities to zero press and hold the button for approximately three seconds until C is di...

Страница 6: ...n can be assigned a batch quantity 1 Setting batch quantities for coin rolls Press and hold the button for approximately three seconds until L is shown in the display This automatically programs each coin denomination for bank coin roll amounts as follows 7 Denomination Quantity 1 25 25 40 10 50 5 40 1 50 Denomination Quantity 1 100 25 350 10 900 5 450 1 300 2 Setting batch quantities for coin tra...

Страница 7: ......

Страница 8: ...nd display a message on the control panel For example after the first batch of 50 pennies has been counted the front panel will display 1c 50 quantity reporting or 1c 0 50 value reporting Note When operating in batch mode the KCS 2000 will keep a running total for each denomination coin For example after four batches of 50 pennies have been dispensed the KCS 2000 will stop and display 1c 200 quant...

Страница 9: ...l parts of the machine with an air duster or a soft cloth Do not use solvents as they may damage the KCS 2000 2 Remove the three housing screws and carefully lift up the housing 3 Remove any foreign objects from the distribution plate 4 Vacuum or use the air duster to clean the dust left in the distribution plate 5 Clean all sensors using an air duster followed by a microfiber cloth lightly moiste...

Страница 10: ... coins from the distribution plate Refer to section 3 1 Turn the unit on and restart counting If the error persists contact Kolibri Technical Service Center refer to section 3 4 16 3 3 Warranty The KCS 2000 is warranted for a period of one year from the date of purchase In most cases a unit malfunction can easily be corrected by performing a thorough cleaning Customer should allow the manufacturer...

Страница 11: ...n with you Product Model Located on the back side of the machine Serial Number Located on the bottom of the machine Nature of the problem What happened and when did it happen Did the machine display an error message Steps Taken Steps already taken to resolve the problem and the results if any Kolibri 2019 Printed in China Specifications subject to change without notice www KolibriUSA com FNKCD2000...

Отзывы: