background image

Directives

Standards

•  Low Voltage Directive

 2014/35/EU

•  IEC 60335-2-54:2002

•  IEC 60335-1:2010

•  EN 60335-1:2012

•  EN 60335-2-54:2008

•  Electromagnetic Compatibility Directive

 2014/30/EU

•  EN 55014-1:2017

•  EN 55014-2:2015

•  EN 61000-4-2:2009

•  EN 6100-4-3:2006+ A1:2008+ A2:2010

•  Pressure Equipment Directive

 2014/68/EU

•  Restriction of Hazardous Substances in Electrical 

and Electronic Equipment Directive

 2011/65/EU

EU declaration of conformity

With this declaration, we confirm that the mentioned device with its design and mode of 

operation meets all safety and health requirements of EU standards. This point expires in 

the event of tampering with the device by an unauthorized person. 

MANUFACTURER:

 Kolektor Mobility d.o.o, Vojkova ulica 10, 5280 Idrija, Slovenia

PRODUCT: 

Cordless pressure sprayer

TYPE: 

25.3

ARTICLE no: 

1014767

Year of affixing the CE marking: 

2022

Authorized person for documentation: 

Sara Trček

 

 

 

 

 

 

 

 

Place and date, 

 

 

 

Name and signature of responsible person

:

Idrija, April 1st 

   

  

 

 

    

 

  Klemen Petrič 

Содержание LIQUISHOT 25.3

Страница 1: ...01 Cordless pressure sprayer PROFESSIONAL ERGONOMIC DEVICE FOR APPLYING LIQUIDS EN...

Страница 2: ......

Страница 3: ...on and rechargeable battery 09 Use of the cordless pressure sprayer 11 Supply via water supply network 12 Supply via the included bucket standing medium source 13 Flow adjustment during operation 13 6...

Страница 4: ...vice is not a toy therefore it is forbidden for the children to use it for play A standard connection must be used when connecting the device to the water supply It is forbidden to consume water pumpe...

Страница 5: ...in use must not come into contact with office staples coins keys nails screws or other small metal objects that could cause bridging of the contacts Short circuit between the contacts may result in b...

Страница 6: ...e hot atmosphere In this case the device stops itself Allow the device to cool before using it again In the event of low voltage low battery the device stops automatically In this case it is necessary...

Страница 7: ...When using a device connected to the water supply network it is necessary to check that the outlet pressure from the water supply does not exceed the permissible inlet pressure specified in the techni...

Страница 8: ...o 3 Product components Hose adapter Universal nozzle Release button lock Release button Waterproof battery protection Cordless pressure sprayer Rotary knob for flow control Battery charge indicator LE...

Страница 9: ...ch Power Tools GmbH professional batteries at various Bosch charging stations min Rechargeable battery capacity State of charge 2Ah 4Ah 5Ah Bosch battery model Charging station 80 100 80 100 80 100 Ba...

Страница 10: ...A Sound power level LWA 74 dB A 2 Uncertainty KWA 2 dB A Measuring process 1 EN 60335 2 54 2 EN 60335 2 79 Position of the flow adjustment button Min 25 Medium 75 Max Achieved fluid pressure bar 5 50...

Страница 11: ...id flow l h 103 20 130 80 153 60 176 40 200 40 Operating time h 305 125 63 34 19 The tests were performed with water at room temperature of the medium and the environment 22 C WARNING Maximum time of...

Страница 12: ...heat up This is normal and does not cause a malfunction The battery can be charged at any time regardless of the state of discharge Charging with a fully discharged battery does not affect the efficie...

Страница 13: ...In this case the user should remove the battery from the charging station and clean the battery contacts with a dry cloth If the indicator still flashes seek professional help or purchase a new set of...

Страница 14: ...ery The waterproof protection must not be stretched as you can destroy it this way The method of placing the waterproof protection when removing the battery and when using the device is shown in Photo...

Страница 15: ...ider is in the middle position the button is released Slider positions are shown in the Photo 8 When using the button lock function the device must not be operated unattended as if the battery is disc...

Страница 16: ...y to install a filter on the hose If the filter is not used internal components may get damaged which results in reduced operating efficiency or failure of the device The connection method is symbolic...

Страница 17: ...the device during storage If the waterproof protection gets dirty it must be carefully removed from the device washed dried properly and carefully put back on When removing placing back the waterproof...

Страница 18: ...ceed the permitted values Reduce the water supply flow 7 Cleaning of device The battery must be removed before cleaning the device Immersion of the gun in the medium or direct spraying of the gun is n...

Страница 19: ...elease button is stuck after using the left slider position lock Too high press force on the release button Presence of foreign body impurity between the release button and the housing Shift to the ri...

Страница 20: ...educed flow or increased outlet pressure can be caused by a clogged filter on the suction side when pumping medium from a free source or bucket e g stones dirt The filter must be cleaned regularly and...

Страница 21: ...ice is shown in Photo 22 Photo 23 Straight extension Articulate extension allows the adjustment of the jet direction 45 It is intended for use on hard to reach areas It allows the connection of the sh...

Страница 22: ...ately After cleaning objects with a medium containing hazardous substances or after cleaning objects contaminated with hazardous substances various cleaning agents chemicals oil the waste medium must...

Страница 23: ...5 The contact form is also available on the website https www liqui shot com technical support Warranty period The seller provides a 24 month warranty period The warranty takes effect on the day of pu...

Страница 24: ...forms the same function and has the same or better technical characteristics and specifications than the original defective part In the event of a defect that does not meet the warranty conditions the...

Страница 25: ...Defects due to improper maintenance of the device Defects due to improper power supply too high pressure on the water supply connection incorrect voltage supply More technical details are available in...

Страница 26: ...11 65 EU EU declaration of conformity With this declaration we confirm that the mentioned device with its design and mode of operation meets all safety and health requirements of EU standards This poi...

Страница 27: ......

Страница 28: ...26...

Отзывы: