Owner’s Manual

Please read and save this manual. Read carefully before attempting to assemble, install, operate or maintain
the product described.
Protect yourself and others by observing all safety information. Failure to comply with manual could result in
personal injury and/or property damage! Retain manual for future reference.

Features

Koldwave 6SS12BEA2ACA0 / 6SS24BGA2ACA0 are designed for a fast installation 

and start up. The split systems are designed for applications where ducting condenser 

discharge air is not practical. The outdoor unit removes condenser heat through a glycol 

loop and can be located up to 30ft away from the indoor unit. The units do not require 

an external water source. All glycol/water mixture is provided with the unit. With 2 fan 

speeds the indoor units allow for quiet operation for office settings or any application 

where noise can be a factor. With their durable metal construction and 4 wheels, they 

are very useful for rental. Integral control panel has troubleshooting features and clear 

indications of unit operation. The units have a “spot cool” or “room cool” functions. The 

spot cool is designed to deliver very cold air for a continuous amount of time. The room 

cool feature is designed to work with a set-point based on room air. The unit will turn on 

and off by an integral return air sensor.

Typical Uses

Computer server rooms, Tents, Offices, Events Marquees, Warehouses, Military uses, Commercial kitchens, 

Hospitals, Schools, Reception areas

Specifications

6SS12BEA2ACA0/

6SS24BGA2ACA0

Figure 1

Split Portable

Air Conditioner

6SS12BEA2ACA0 / 6SS24BGA2ACA0

Model

Cooling Capacity

Refrigerant

Electrical Supply

Rated Current

Amps

Operating Range

6SS12BEA2ACA0

12,000BTU (3.5kW)

R410A (1.2 lbs)

115V, 1phase, 60hz

12.3A

64-113°F (18-45°C)

6SS24BGA2ACA0

22,000BTU (6.5kW)

R410A (1.61 lbs)

220V, 1phase, 60hz

12.3A

64-113°F (18-45°C)

Model

Depth/Width/

Height/Weight

(Indoor Unit)

Depth/Width/

Height/Weight

(Outdoor Unit)

Fan Speeds

Air Flow (high/low)

Noise Level at 3m

(Indoor Unit, high/low)

Control

6SS12BEA2ACA0

27.75 / 13.77 /

36.5 inch

/183Lbs

26 / 10.82 /

25.78 inch

/ 48.5Lbs

2

258 / 219 CFM

40 / 36 dBA

Integral

6SS24BGA2ACA0

27.75 / 13.77 /

36.5 inch

/205Lbs

27.6 / 10.82 /

27.8 inch

/ 59.5Lbs

2

653 / 565 CFM

58 / 54 dBA

Integral

NOTE:

 Refrigerant and Electrical supply can be different per country. Please check the label on the unit for 

proper information.

SP-IOM-1

Содержание 6SS12BEA2ACA0

Страница 1: ...ot cool or room cool functions The spot cool is designed to deliver very cold air for a continuous amount of time The room cool feature is designed to work with a set point based on room air The unit...

Страница 2: ...electrician and all local electrical codes to ensure proper setup Any extension cord used with this device must be rated for a minimum of 15A 18 DO NOT unplug the unit by pulling on the electrical cor...

Страница 3: ...haust part discharge of hot air Electrical part Electrical control box Side handle Cooling water air purge control CONDENSER Fresh air inlet for cooling nonfreezing cooling water Caster Figure 2 Figur...

Страница 4: ...ther foreign material Do not use the unit in explosive environments or in areas where flammable gas leakage may occur If the power cord or plug is damaged repair should only be performed by qualified...

Страница 5: ...be memorized and compressor will stop after the time set Figure 7 5 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual 5 WSC 4000 WSC 6000 Owner s manual Operation CONTROL PANEL 1 POWER BUTTON Activates unit...

Страница 6: ...eration If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation Customer Please read and keep this manual fo...

Страница 7: ...air filter b Ambient temperature is too high c Cooling pump is not operate normally d Power is not supplied to outdoor unit TH1 outlet temperature sersor has a loose or broken connection TH2 inlet tem...

Страница 8: ...8 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 Wiring Diagram 8 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual Wiring Diagram Figure 10 Circuit Wiring Diagram Figure 10 Circuit Wiring Diagram...

Страница 9: ...ool 1 Only BlOWER light on ROOM COOL and SPOT COOL light off 2 Compressor will start in 2 minutes after unit is restarting 3 The ambient temperature may be too high 1 Press ROOM COOL button or SPOT CO...

Страница 10: ...our dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call Koldwave Portable Air Conditioner Technical Support at 413 564 5530 Please have the following infor...

Страница 11: ...11 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0...

Страница 12: ...2 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 260 North Elm St Westfield MA 01085 Phone 413 564 5520 Fax 413 564 5530 www koldwave com For Koldwave warranty please visit http koldwave com warranty aspx...

Отзывы: