General Safety Information

Please read this manual carefully for instructions on correct installation and usage. Please read all safeguards.

1.  Transport and store the unit in an upright position only. Leave unit in an upright position for at least 3 hours 

before first use.

2.  Always place the unit on an even, level surface.

3.  Ensure the unit is connected to a grounded power supply of the correct rating / capacity.

4.  The unit will cool when the room temperature is between 64.4°F (18°C) – 122°F (50°C) depending on the 

thermostat setting.

5.  DO NOT use this unit for functions other than those described in this instruction manual.

6.  DO NOT tilt the unit.

7.  DO NOT cover or obstruct the unit’s inlet and outlet grilles.

8.  DO NOT use the unit in areas where it will be exposed to rain or water.

9.  NEVER unplug the unit while it is operating.

10. DO NOT place any foreign objects on the unit.

11.  DO NOT operate the unit with wet or damp hands.

12. DO NOT allow chemical substances to come into contact with the unit.

13. DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols, pesticides, 

gasoline, etc.

14.  DO NOT use the plug to start and to stop the unit. Always use the control panel to start and to stop the unit.

15.  Always turn off the unit when it is not in use and unplug the power plug from the electrical outlet.

16.  Always turn the unit off and unplug the main power plug from the electrical outlet before cleaning, moving or 

performing maintenance.

17.  AVOID the use of adapter plugs or extension cords. If it is necessary to use an extension cord or an adapter plug 

to operate the unit, ensure that they are correctly rated for the application. Consult a local qualified electrician 

and all local electrical codes to ensure proper setup. Any extension cord used with this device must be rated for a 

minimum of 15A.

18.  DO NOT unplug the unit by pulling on the electrical cord. Keep electrical cord away from heat sources and always 

completely unroll the cord to avoid overheating. If the power cord becomes damaged, a qualified service agent, 

qualified electrician, or similarly qualified person must replace it, in order to avoid a hazard or shock.

19.  The filters must be used with the product at all times. When the filters are removed for cleaning, always ensure that 

the unit has been turned off and unplugged from the electrical outlet.

20.  Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the units output performance 

and efficiency will decline and energy consumption will increase.

21.  DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or damaged.

22.  Only use in the upright position on an even, flat surface. Unit must be positioned at least 24 inches (60 cm) from 

the nearest object in front.

23.  Stop operation immediately if abnoraml noise or odor is noticed. Contact a local service center.

24.  Appliance is not to used by children or persons with reduced physical, sensory or mental capabilities, or lack of 

experience and knowledge, unless they have been given supervision or instruction.

25.  Children being supervised not to play with appliance.

26.  That the appliance shall be installed in accordance with national wiring regulations.

27.  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard.

SAVE THESE INSTRUCTIONS

DO NOT use the unit in wet environments, such as a laundry room, to avoid

the risk of electrical shock.

DO NOT operate the unit in explosive or flammable environments.

DO NOT operate a unit with a damaged power cord.

Содержание 6SS12BEA2ACA0

Страница 1: ...ot cool or room cool functions The spot cool is designed to deliver very cold air for a continuous amount of time The room cool feature is designed to work with a set point based on room air The unit...

Страница 2: ...electrician and all local electrical codes to ensure proper setup Any extension cord used with this device must be rated for a minimum of 15A 18 DO NOT unplug the unit by pulling on the electrical cor...

Страница 3: ...haust part discharge of hot air Electrical part Electrical control box Side handle Cooling water air purge control CONDENSER Fresh air inlet for cooling nonfreezing cooling water Caster Figure 2 Figur...

Страница 4: ...ther foreign material Do not use the unit in explosive environments or in areas where flammable gas leakage may occur If the power cord or plug is damaged repair should only be performed by qualified...

Страница 5: ...be memorized and compressor will stop after the time set Figure 7 5 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual 5 WSC 4000 WSC 6000 Owner s manual Operation CONTROL PANEL 1 POWER BUTTON Activates unit...

Страница 6: ...eration If the fault persists for more than 3 minutes the evaporator fan also stops The fault must be rectified before the unit can resume normal operation Customer Please read and keep this manual fo...

Страница 7: ...air filter b Ambient temperature is too high c Cooling pump is not operate normally d Power is not supplied to outdoor unit TH1 outlet temperature sersor has a loose or broken connection TH2 inlet tem...

Страница 8: ...8 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 Wiring Diagram 8 6SS12BEA2ACA0 6SS24BGA2ACA0 Owner s Manual Wiring Diagram Figure 10 Circuit Wiring Diagram Figure 10 Circuit Wiring Diagram...

Страница 9: ...ool 1 Only BlOWER light on ROOM COOL and SPOT COOL light off 2 Compressor will start in 2 minutes after unit is restarting 3 The ambient temperature may be too high 1 Press ROOM COOL button or SPOT CO...

Страница 10: ...our dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call Koldwave Portable Air Conditioner Technical Support at 413 564 5530 Please have the following infor...

Страница 11: ...11 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0...

Страница 12: ...2 Owner s Manual 6SS12BEA2ACA0 6SS24BGA2ACA0 260 North Elm St Westfield MA 01085 Phone 413 564 5520 Fax 413 564 5530 www koldwave com For Koldwave warranty please visit http koldwave com warranty aspx...

Отзывы: