DO NOT operate a unit with a damaged power cord.

19.  The filters must be used with the product at all times. When the filters are removed for cleaning, always 

ensure that the unit has been turned off and unplugged from the electrical outlet.

20. Regularly clean the filters to maintain efficiency. If the filters are not cleaned regularly, the units output 

performance and efficiency will decline and energy consumption will increase.

21.  DO NOT operate the unit with a damaged power cord or plug, after it malfunctions, has been dropped or 

damaged.

22. Only use in the upright position on an even, flat surface. Unit must be positioned at least 24 inches (60 cm) 

from the nearest object in any direction.

23. Stop operation immediately if abnormal noise or odor is noticed. Contact a local service center.

24.  Appliance is not to used by children or persons with reduced physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they have been given supervision or instruction.

25. Children being supervised not to play with appliance.

26. That the appliance shall be installed in accordance with national wiring regulations.

27.  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified 

persons in order to avoid a hazard.

SAVE THESE INSTRUCTIONS

Содержание 6HK13BEH0

Страница 1: ...y showing operating modes room and set temperatures and faults If an abnormal operation occurs a visual display of the fault is shown Caster wheels are included for easy portability Suitable applicati...

Страница 2: ...blem is not corrected please collect information so that the Technical Support personnel can more effectively assist you Model No Weight Net Gross Lbs kg Condensate Tank Gallons Liters Setting Tempera...

Страница 3: ...p hands 12 DO NOT allow chemical substances to come into contact with the unit 13 DO NOT operate the unit in the presence of flammable substances or vapors such as alcohols pesticides gasoline etc DO...

Страница 4: ...d 22 Only use in the upright position on an even flat surface Unit must be positioned at least 24 inches 60 cm from the nearest object in any direction 23 Stop operation immediately if abnormal noise...

Страница 5: ...ith the top fan exhaust flange to install the top fan exhaust flange on the unit as shown in Figure 6 TOP FAN EXHAUST FLANGE Figure 6 Figure 7 Figure 8 A B C Condenser plenum can be purchased separate...

Страница 6: ...caster brakes to the locked position PLUGGING IN THE UNIT Check the prongs and surface of the power cord plug for dust dirt If dust and or dirt are present wipe off with a clean dry cloth Check the p...

Страница 7: ...After setting the target temperature press TEMP SELECT BUTTON for 2 seconds and SET lamp will be off and setting temperature will be memorized 7 6HK13BEHO Owner s Manual Oper on CONTROL PANEL 1 POWER...

Страница 8: ...ose 7 by pressing UP DOWN BUTTON Choose 0 by pressing UP DOWN BUTTON Press MODE BUTTON for 2 seconds then figure will change to C 8 TARGET TEMP Displays the unit set temperature When OUT lamp is on in...

Страница 9: ...purchase 9 Maintenance FILTER CLEANING See Figures 10 and 11 There are two filters in the unit The evaporator filter is located at the front of the unit The condenser filter is located at the back of...

Страница 10: ...3 minutes the evaporator fan also stops The fault must be r fied before the unit can resume normal oper on There are two springs on the rear of condensate water tank guide 1 Release the screw on the...

Страница 11: ...11 Owner s Manual 6HK13BEH0 11 6HK13BEHO Owner s Manual Table 1 1 Alarm Codes Table 1 1 Alarm Codes...

Страница 12: ...12 Owner s Manual 6HK13BEH0 12 6HK13BEHO Owner s Manual Table 1 2 Alarm Codes Table 1 2 Alarm Codes...

Страница 13: ...13 Owner s Manual 6HK13BEH0 Wiring Diagram 6HK13BEHO Owner s Manual Wiring Diagram Figure 13 6HK13BEHO...

Страница 14: ...Ambient air cannot be properly cooled if the filter is dirty and not regularly cleaned 1 Clean the filter 2 Compressor will not work if the unit is turned off and on quickly 2 Wait 2 minutes a er uni...

Страница 15: ...tor Fan KWPHFANE 03 Condenser Fan KWPHFANC 03 Cap Evaporator Motor KWPHCAPM 03E Cap Condenser Motor KWPHCAPM 03C HP Sensor KWPHHPS 01 LP Sensor KWPHLPS 01 Compressor KWPHCOMP 03 Comp Cap KWPHCAPC 03 T...

Страница 16: ...lacement of all parts hereunder shall not operate to extend the original warranty period as to any part including replacement parts supplied hereunder THE ABOVE WARRANTY HEREWITH SET FORTH IS IN LIEU...