To Select Operating Mode: 

To choose the operating mode, press the 

“Mode” button. Each time you press the button a mode 

is selected in a sequence that cycles from Auto -> Cool -> Energy Saver -> Fan Only -> Dry. The 
indicator light beside the mode button will be illuminated and remain on once the mode is 
selected. 

To Operate in Auto Mode: 

 

When you set the unit to “Auto” mode the unit will automatically select cooling or fan 
only operation: Whichever will reach and maintain the default cooling temperature 
setting of 66°F. 

 

When the ambient room temperature is above 66°F, the unit will turn on the compressor 
to begin cooling. Once this temperature is achieved, the unit will then switch to fan only 
mode in order to maintain this temperate. This process will repeat, as necessary. 

 

In this mode, the set temperature cannot be adjusted. It will start automatically at a 
speed calibrated to the actual room temperature. 

 
 
 
 
 
 
 
 
 
 

To Operate in Cool Mode:  

 

When the unit is set to “Cool” mode it will cool the room to maintain the desired set 
temperature.   

  When the desired temperature has been reached, the unit will automatically maintain the 

temperature.  

  Press the Up and Down buttons to adjust the desired temperature and press the Fan 

Speed button to adjust the fan speed. 

To Operate in Energy Saver Mode: 

  In this mode, the air conditioner will attempt to save energy by cooling less frequently 

while still trying to maintain the desired set temperature. 

  The Fan Speed can still be adjusted. 

To Operate in Fan Only Mode: 

 

Use this function only when cooling is not desired, such as for room circulation or to 
exhaust air. You can choose any speed you prefer, though the “Auto” fan speed is not 
an available option. 

 

In Fan Only mode, you cannot adjust the set temperature. 

To Operate in Dry Mode: 

 

In this mode, the air conditioner will operate as a dehumidifier. Because the conditioned 
space is closed or sealed, some degree of cooling will continue to occur. 

 

The air conditioner runs at the Low fan speed, which cannot be adjusted. 

 

Note:  

 The unit does not constantly take temperature readings. The unit will take a temperature 

reading periodically while operating in AUTO mode, or immediately upon adjustment of the 
desired set temperature.   

 When operating in AUTO MODE the unit may not switch between Cool and Fan Mode at the 

exact moment when a temperature change has occurred.   

 Room temperature may be different than the temperature sensed in front of the air conditioner. 

Содержание WAC6002WCO

Страница 1: ...V2 5 11212019 Window Air Conditioner Owner s Manual For more information on other great Koldfront products on the web go to https www koldfront com WAC6002WCO...

Страница 2: ...outlet with another appliance Do not use this unit with an extension cord and or adapter plug Do not use this unit near flammable gases combustibles or in close proximity to heating appliances During...

Страница 3: ...hould trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact Koldfront support DO NOT USE YOUR WINDOW AIR CONDITIONER IF T...

Страница 4: ...Preparing the Unit for Window Installation 4 Installing Air Conditioner into Window 6 Completing Installation 7 CONTROL PANEL OPERATIONS 9 Using the Control Panel 9 REMOTE OPERATIONS 12 Installing the...

Страница 5: ...numbers are located on the ratings label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase...

Страница 6: ...2 Parts Identification Side View Front View...

Страница 7: ...e you begin make sure you have all the parts necessary for installation If you have multiple windows choose one that is near an electrical outlet that will be able to provide sufficient power to your...

Страница 8: ...itioner cabinet lining up the four holes in the top channel with the four holes on top of the cabinet 4 Using the four supplied Type A screws attach the top channel to the air conditioner cabinet 5 To...

Страница 9: ...g the Window for Installation 1 Cut the adhesive window sealing strips into the proper length for your window Tear off the adhesive cover on the back of one of the strips and attach the sealing strip...

Страница 10: ...window sash to hold the cabinet in place Measure the distance of the right side and left and adjust the air conditioner s placement until it is centered in the window frame 2 Attach the side curtains...

Страница 11: ...ne non adhesive window sealing strip into a length equal to the width of the window 2 Once the strip has been cut to the proper length insert it between the upper window and the glass This will help p...

Страница 12: ...e curtain The extra material on top of the sections can be tucked into the upper window to keep them in place 5 Plug into a grounded 3 prong outlet 6 Press Reset on the power cord supply 7 Press the o...

Страница 13: ...maintained anywhere between 61 F 16 C and 86 F 30 C To Adjust Fan Speeds To select the speed of the fan press the Fan Speed button which cycles through four 4 steps Auto Low Medium and High Each time...

Страница 14: ...erature Press the Up and Down buttons to adjust the desired temperature and press the Fan Speed button to adjust the fan speed To Operate in Energy Saver Mode In this mode the air conditioner will att...

Страница 15: ...n the Air Filter for more efficient operation The LED light will illuminate after 250 hours of operation To reset after cleaning the filter press the Filter Check button and the indicator light will t...

Страница 16: ...will send the ambient temperature value to the air conditioner every 10 minutes Fan and temperature adjustments are then made according to the temperature measured at the remote s location Sleep This...

Страница 17: ...e temperature display between degrees Celsius and Fahrenheit Light Function While the unit is either off or on you may hold the Increase and Fan buttons simultaneously for three 3 seconds to turn the...

Страница 18: ...sides of the air conditioner 3 Grasp the filter pull up and out 4 Wash the filter using liquid dishwashing detergent and warm water Rinse the filter thoroughly 5 Gently shake excess water from the fil...

Страница 19: ...ed by the fan Gurgle Hiss Gurgling or Hissing noise may be heard due to refrigerant passing through the evaporator during normal operation Vibration The unit may vibrate and make noise because of poor...

Страница 20: ...a warmer climate Minimize the heat sources direct sunlight computers servers people etc in the room Close all windows and doors Use the unit in a contained room For example a room with four walls and...

Страница 21: ...does not feel cold enough Room temperature is below 61 17 Cooling will not occur until room temperature rises above 61 17 Temperature sensor behind the front grill and air filter is touching the cold...

Страница 22: ...ner turns on and off frequently Dirty air filter air restricted Clean air filter Outside temperature is extremely hot Set FAN speed to a Higher setting to push more air through the coils Noise when un...

Страница 23: ...product Window Air Conditioner Model WAC6002WCO Voltage Frequency 115V 60Hz Cooling Capacity BTUs 6050 Current 4 6A Color White Coolant R410A 14 82 oz Timer 24 Hour Dimensions W x D x H 18 9 16 x 15...

Страница 24: ...on or commercial use Labor service transportation and shipping charges for the removal and replacement of defective parts beyond the initial 24 month period Products that have been modified to perform...

Отзывы: