Koldfront Window Air Conditioner
16
Troubleshooting
Follow the troubleshooting guide below to resolve common issues.
Issue Possible
Cause
Solution
My air conditioner is not
functioning at all
Wall plug
disconnected
Make sure the unit is
plugged in
LCDI power cord is
tripped
Press the Reset button
on the LCDI cord
House fuse blown or
circuit breaker tripped.
Replace fuse with time
delay type or reset circuit
breaker
Control panel is off
Turn control panel ON
and set to desired setting
Insufficient power
Move the unit to another
outlet. Check your circuit
breaker. (Refer to the
rating label on the back
of the unit to determine
the Amperage draw)
Air from unit does not
feel cold enough
Room temperature
below 17°C (62°F)
Cooling may not occur
until room temperature
rises above 17°C (62°F)
Compressor shut-off
by changing modes
Wait approximately 3
minutes and listen for
compressor to restart
when set in the COOL
mode
Air conditioner is cooling
but room is too warm,
ice is forming on cooling
coil behind decorative
front
Outdoor temperature
below 18°C (64°F)
To defrost the coil, set
FAN ONLY mode
Air filter may be dirty
Clean Filter. Refer to
maintenance section. To
defrost, set to FAN ONLY
mode
Unit needs to be
defrosted
To defrost the coil, set to
FAN ONLY mode. Then,
set temperature to higher
setting
Air conditioner is cooling
but room is too warm,
NO ice is forming on
cooling coil behind
decorative front
Dirty air filter, air
restricted
Clean air filter. Refer to
maintenance section
Temperature is set too
High
Set temperature to lower
setting
Air directional louvers
positioned improperly
Position louvers for better
air distribution
Front of unit is blocked
by drapes, blinds,
furniture, etc., restricts
air distribution
Clear blockage in front of
unit