Koldfront WAC10002WCO Скачать руководство пользователя страница 11

 
 

10 

 
 

 

 

 

No. 

Part Name 

No. 

Part Name 

Panel assembly 

19 

Fan motor 

1.1 

Front panel 

21 

Suction pipe 

1.2 

Panel frame 

22 

Compressor 

1.2.1 

Horizontal louver 

23 

Parts of compressor exhaust pipe 

1.2.2 

Panel frame 

24 

Evaporator assembly 

1.2.3 

Connecting rod of louver 

24.1 

Evaporator 

1.2.4 

Horizontal louver 

24.2 

Capillary tube assembly 

1.2.5 

Horizontal louver 

25 

Condenser assembly 

Filter 

26 

Chassis assembly 

Remote control 

28 

Upper shutter frame 

Electronic control box assembly 

29 

Shell 

7.3 

Room temperature sensor 

30 

Installation accessories 

7.5 

Power supply cord 

30.1 

Left shutter frame 

7.6 

Main control board subassembly 

30.2 

Shutter 

7.7 

Electronic control box 

30.4 

Right shutter frame 

7.8 

Capacitor 

30.6 

Shutter clamp 

10 

Fresh air door 

30.7 

Installing L plate 

11 

Centrifugal fan 

30.9 

Shutter 

12 

Volute shell (below) 

32 

Display box assembly 

15 

Volute shell assembly 

32.1 

Display board assembly 

15.1 

Upper volute shell 

32.2 

Control panel 

15.2 

Wind baffle board 

36 

Cover of electronic control box 

15.3 

Mid volute shell 

37 

Installation accessories 

15.4 

Bracket of fresh air door 

37.1 

Sponge 

17 

Fan housing 

38 

Fixing board 

18 

Axial fan 

39 

Fixing board 

 

Содержание WAC10002WCO

Страница 1: ...y service should be performed by an authorized service representative only SERVICE MANUAL Koldfront Cool Only Window Air Conditioner MODELS COVERED WAC8002WCO WAC10002WCO WAC12002WCO Document Type Ser...

Страница 2: ...INSTRUCTIONS 14 4 1 DISPLAY PANEL CONTROLS 14 4 2 REMOTE CONTROLS 16 5 INSTALLATION AND CLEANING 17 5 1 PROPER INSTALLATION AND DRAINAGE 17 5 2 CLEANING THE FILTER 18 6 MODES AND OPERATING CONDITIONS...

Страница 3: ...may occur Common sense caution and care must be exercised To prevent electric shock always unplug an appliance from the power supply before attempting any service Disconnect the power cord by grasping...

Страница 4: ...iance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords or p...

Страница 5: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 6: ...5 1 Exploded Diagrams and Part Lists 1 1 WAC8002WCO...

Страница 7: ...ute shell 1 8 Display box assembly 20 2 Top volute shell 2 Evaporator assembly 22 Electronic control box assembly 3 Compressor 22 2 Electronic control box 4 Condenser assembly 22 3 Main control board...

Страница 8: ...7 1 2 WAC10002WCO...

Страница 9: ...out 26 Chassis assembly 7 3 Room temperature sensor 28 Upper shutter frame 7 5 Power supply cord 29 Shell 7 6 Main control board subassembly 30 Installation accessories 7 10 Electrical control box cov...

Страница 10: ...9 1 3 WAC12002WCO...

Страница 11: ...29 Shell 7 3 Room temperature sensor 30 Installation accessories 7 5 Power supply cord 30 1 Left shutter frame 7 6 Main control board subassembly 30 2 Shutter 7 7 Electronic control box 30 4 Right shu...

Страница 12: ...11 1 4 Dimensions Width Height Depth WAC8002WCO 18 1 2 471 mm 13 3 8 340 mm 17 1 2 444 mm WAC10002WCO WAC12002WCO 19 482 mm 14 5 8 372 mm 21 1 2 545 mm...

Страница 13: ...12 2 Wiring Diagram All Models...

Страница 14: ...and Main PCB 3 3 Sensor and Display Connections on Main PCB All sensor connections are clearly marked on the PCB Room Def and are located near the display ribbon cable connection Refer to this diagram...

Страница 15: ...for 3 seconds will change the display from to Mode select Button To choose the operating mode press Mode Each time you press the button a mode is selected in a sequence that goes from Auto Cool Dry to...

Страница 16: ...tton In this mode the selected temperature will increase by 2 F 1 C 30 minutes after the mode is selected The temperature will then increase by another 2 F 1 C after an additional 30 minutes This new...

Страница 17: ...te signal receiver sensor is located on the control panel of the air conditioner Reception of signal commands is confirmed by an audible beep Direct sunlight can interfere with the infrared signal To...

Страница 18: ...l begin to splash and disperse that water over the condenser coils which significantly aids in cooling the internal components and increases the overall efficiency of the unit If there is an over accu...

Страница 19: ...lter thoroughly Gently shake excess water from the filter Be sure the filter is thoroughly dry before replacing You may also gently use a vacuum to clean the filter Reinstall the air filter once it s...

Страница 20: ...FAN in order to achieve and maintain the desired set temperature In Auto mode the unit will choose cooling or fan only mode based on T T TA TS T TA TS Running mode T 4 F Cooling 2 F T 4 F Fan only Th...

Страница 21: ...losed or sealed some degree of cooling will continue to occur The dry mode temperature can be set from 62 to 86 17 to 30 The fan speed is automatically set to Low and can t be controlled Sleep functio...

Страница 22: ...stop defrosting 6 8 Sleep Mode This mode has a duration of 7 hours and can be used in Cool and Dry mode In sleep mode the fan speed will default to Auto In the first 60 minutes the set temp will rise...

Страница 23: ...nit does not feel cold enough Room temperature is below 62 17 Cooling will not occur until room temperature rises above 62 17 Temperature sensor behind the front grill and air filter is touching the c...

Страница 24: ...installation instructions or check with installer Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly downward toward the outside to allow water drainage Re...

Страница 25: ...35 2024 27 80 6 9 1245 54 129 2 2 959 1 33 8 33 3269 28 82 4 8 7198 55 131 2 8442 2 35 6 31 5635 29 84 2 8 3357 56 132 8 2 7382 3 37 4 29 9058 30 86 7 9708 57 134 6 2 6368 4 39 2 28 3459 31 87 8 7 624...

Страница 26: ...l St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Warranty service should be performed by an authorized service representative only DATE REVISION NOTES 04 11 2018...