Thermoelectric Precautions  

This wine cooler uses thermoelectric technology rather than compression or absorption-types and there 
are several issues that need attention: 
  

 

Room temperature -  The wine cooler needs to be located in a climate controlled room.  The unit 
will perform it’s best at a room temperature of approximately 72° to 77

.  It will not cool correctly 

when the room temperature is higher than 90° or lower than 65°F. 

 

Ventilation 

– The wine cooler needs to be free standing.  It should not be recessed or built in (fully 

recessed.)  Allow enough clearance (5”) at the rear and sides of the wine cooler to allow proper 
ventilation. Lack of proper ventilation will have a negative impact on the performance of cooler.  

 

Moisture 

– The wine cooler may have some condensed water on the surface of the glass door if 

opened constantly in a moist place. This moisture will drain into the condensate tray at the back 
of the unit and may require emptying if excessive moisture is collected in a short period of time. 

 
 

Finding a good spot for your wine cooler 

Where you locate the wine cooler is critical to its performance.  Follow these guidelines: 

  

 

Install your wine cooler on a level surface that is strong enough to support it when fully loaded.  

 

Allow 5 inches (15cm) of space  at the rear  and at both sides of the  wine cooler  to allow  proper 
ventilation.   

 

This wine cooler is designed to be free standing only and should not be recessed or built-in (fully 
recessed.) 

 

Do not place heavy objects on top of the unit.  

 

Do not install the unit outside or in a moist place.  

 

Do not install the wine cooler in direct sunlight or next to heat sources. 

 

The unit’s cooling system operates at maximum efficiently with an ambient room temperature of 
72° to 77

.  The interior temperature can be set between 44°F and 66°F and will be most accurate 

in that temperature range. 

 

 

Содержание TWR327ESS

Страница 1: ...EdgeStar 8606 Wall St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Document Type Service Manual Version V1 0 02052018...

Страница 2: ...herein is intended for use by certified technicians The manufacturer or seller is not responsible for the interpretation or misuse of the information provided nor does it assume any liability in conne...

Страница 3: ...appliance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...antly in a moist place This moisture will drain into the condensate tray at the back of the unit and may require emptying if excessive moisture is collected in a short period of time Finding a good sp...

Страница 6: ...ductor materials The complete system includes a semi conductor module P N shape semi conductors clamped with two ceramic chips an internal and external heat exchanger To obtain higher energy efficienc...

Страница 7: ...Exploded View Diagram...

Страница 8: ...Parts List...

Страница 9: ...Circuit Board Diagram...

Страница 10: ...TWR327ESS Voltage Frequency 115V 60Hz Power 140W Rated Current 1 9A Net Weight 56 9 lbs Note Specifications are subject to change Check the rating label on the back of unit for the most accurate infor...

Страница 11: ...Supply Board Connector Arrangement 1 Power cord 2 Thermoelectric Module 3 Heating fan 4 Cooling fan 5 Temperature Controller NOTE All wiring connections need to be attached securely to the board 1 5...

Страница 12: ...r Supply Board 1 Remove the back panel on the unit and disconnect the wire connectors on the board 2 Remove screws 4 from the board 3 Replace the board and reattach the screws 4 4 Reconnect the connec...

Страница 13: ...rom the board Remove screws 2 from the rear of the door 3 Remove screws 2 from the rear of the temperature controller 4 Pull out old temperature controller disconnect the wire connector and replace wi...

Страница 14: ...Thermoelectric Module and Heat Fan Thermoelectric Node Heat side has printing Heat sink Cool sink...

Страница 15: ...and Heat Fan 1 Remove the module and the heat fan connectors 2 Remove the screws for the heat fan and replace with new fan 3 Remove the screws for the module and replace with new module 4 Reconnect th...

Страница 16: ...g The Heat Fan 1 Remove the screws 2 Replace the fan and reinstall the screws Replacing the Cooling Fan 1 Pull out the plastic caps 4 on the cooling fan cover 2 Removing the screws 4 on the cooling fa...

Страница 17: ...opening the cooling fan cover 4 Remove the screws 4 from the cooling fan 5 Replace the old cooling fan and reconnect the wire 6 Be careful not to damage the wire 7 Fix the sensor into the proper posit...

Страница 18: ...the screws 2 on the cold sink of the module 2 Carefully disassemble the module and clean any grease residue from the node compartment 3 Apply thermal grease evenly and replace the thermoelectric node...

Страница 19: ...Error Codes...

Страница 20: ...Diagnostics Wine cooler does not cool or will not run NO YES NO YES NO YES NO...

Страница 21: ...EdgeStar 8606 Wall St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com...

Отзывы: