Koldfront TWR327ESS Скачать руководство пользователя страница 4

General Safety 

  Always unplug an appliance from the power supply before attempting any service. Disconnect the 

power cord by grasping the plug, not the cord. 

  Do not allow children or pets to play on or in the appliance.  

  This machine is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 
instruction concerning use of the machine by a person responsible for their safety. 

  Do not install or store this appliance where it will be exposed to the weather. 

  Disconnect from the power socket before cleaning or maintenance.  

  If the plug (power cord) is damaged, it must be replaced by the manufacturer or an authorized service 

representative. 

  This machine shall be repaired only by an authorized service representative. Only genuine 

replacement parts should be used. 

  If connected to a circuit protected by fuses, use time-delay fuses with this appliance. 

  Do not lean items against the glass door. 

  Please do not close the door with excessive force. If it is found difficult to close the door, please check 

for obstruction. 

  When you plan to dispose of this unit in the future, please comply with the local waste disposal 

regulations. Remove the door so that children and pets will not be trapped in the unit. 

 

 

Содержание TWR327ESS

Страница 1: ...EdgeStar 8606 Wall St Suite 1800 Austin TX 78754 support edgestar com service edgestar com edgestar com Document Type Service Manual Version V1 0 02052018...

Страница 2: ...herein is intended for use by certified technicians The manufacturer or seller is not responsible for the interpretation or misuse of the information provided nor does it assume any liability in conne...

Страница 3: ...appliance is properly grounded Do not bypass cut or remove the grounding plug If the power cord is damaged it must be replaced by the manufacturer or a qualified technician Do not use extension cords...

Страница 4: ...exposed to the weather Disconnect from the power socket before cleaning or maintenance If the plug power cord is damaged it must be replaced by the manufacturer or an authorized service representative...

Страница 5: ...antly in a moist place This moisture will drain into the condensate tray at the back of the unit and may require emptying if excessive moisture is collected in a short period of time Finding a good sp...

Страница 6: ...ductor materials The complete system includes a semi conductor module P N shape semi conductors clamped with two ceramic chips an internal and external heat exchanger To obtain higher energy efficienc...

Страница 7: ...Exploded View Diagram...

Страница 8: ...Parts List...

Страница 9: ...Circuit Board Diagram...

Страница 10: ...TWR327ESS Voltage Frequency 115V 60Hz Power 140W Rated Current 1 9A Net Weight 56 9 lbs Note Specifications are subject to change Check the rating label on the back of unit for the most accurate infor...

Страница 11: ...Supply Board Connector Arrangement 1 Power cord 2 Thermoelectric Module 3 Heating fan 4 Cooling fan 5 Temperature Controller NOTE All wiring connections need to be attached securely to the board 1 5...

Страница 12: ...r Supply Board 1 Remove the back panel on the unit and disconnect the wire connectors on the board 2 Remove screws 4 from the board 3 Replace the board and reattach the screws 4 4 Reconnect the connec...

Страница 13: ...rom the board Remove screws 2 from the rear of the door 3 Remove screws 2 from the rear of the temperature controller 4 Pull out old temperature controller disconnect the wire connector and replace wi...

Страница 14: ...Thermoelectric Module and Heat Fan Thermoelectric Node Heat side has printing Heat sink Cool sink...

Страница 15: ...and Heat Fan 1 Remove the module and the heat fan connectors 2 Remove the screws for the heat fan and replace with new fan 3 Remove the screws for the module and replace with new module 4 Reconnect th...

Страница 16: ...g The Heat Fan 1 Remove the screws 2 Replace the fan and reinstall the screws Replacing the Cooling Fan 1 Pull out the plastic caps 4 on the cooling fan cover 2 Removing the screws 4 on the cooling fa...

Страница 17: ...opening the cooling fan cover 4 Remove the screws 4 from the cooling fan 5 Replace the old cooling fan and reconnect the wire 6 Be careful not to damage the wire 7 Fix the sensor into the proper posit...

Страница 18: ...the screws 2 on the cold sink of the module 2 Carefully disassemble the module and clean any grease residue from the node compartment 3 Apply thermal grease evenly and replace the thermoelectric node...

Страница 19: ...Error Codes...

Страница 20: ...Diagnostics Wine cooler does not cool or will not run NO YES NO YES NO YES NO...