Koldfront PAC701W Скачать руководство пользователя страница 19

Koldfront Portable Air Conditioner  

 

16 

Troubleshooting 

 
Follow the troubleshooting guide below to resolve common issues. 

Issue Possible 

Cause 

Solution 

My air conditioner is 
not functioning at all. 

Unit is not receiving 
power. 

Make sure the unit is 
plugged in to a 
grounded outlet. 

LCDI power cord is 
tripped. 

Press the Reset button 
on the LCDI cord. 

Insufficient power. 

Move the unit to 
another outlet. Check 
your circuit breaker. 
(Refer to the rating 
label on the back of 
the unit to determine 
the Amperage draw). 

Water reservoir is full. 

Drain the unit and 
restart. 

Control panel is 
disconnected. 

If no indicator lights 
turn on, contact 
customer service. 

My remote control 
does not work and the 
indicator light on 
remote does not turn 
on. 

Batteries not installed. 

Install new batteries. 

Bad batteries. 

Replace the batteries. 

Batteries installed 
incorrectly. 

Reinstall the batteries 
correctly. 

A defective remote 
control. 

Contact customer 
service. 

My air conditioner is 
making a loud noise. 

The unit is not level. 

Make sure the unit is 
on a level surface. 

A foreign object has 
jammed the fan. 

Remove the object 
from the fan. 

The floor below the 
unit is uneven. 

Move the unit to a 
level surface. 

My air conditioner is 
making a continuous 
metallic knocking or 
pinging sound. 

Unit may have been 
shipped on its side. 

Shut off the unit. Let 
the unit sit on a level 
surface for at least 24 
hours and restart. 

Damaged compressor.  Contact customer 

service. 

My air conditioner is 
leaking. 

Drain plug is removed. 

Attach the drain plug. 

Cracked base pan. 

Contact customer 
service. 

My air conditioner runs 
for a little while and 
then it trips the power 
cord or the circuit 
breaker. 

The air conditioner 
may be plugged into 
an outlet that can not 
supply the correct 
amount of current. 

Contact an electrician 
if the unit works in a 
different room or 
circuit. 

The control panel 
lights blink randomly. 

Unit may have a faulty 
control panel. 

Contact customer 
service. 

No air comes out the 
left side of the air vent. 

The unit is designed to 
blow air from the right. 

This is normal 
operation. 

 

Содержание PAC701W

Страница 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com PAC701W...

Страница 2: ...designed for indoor use only Do not use the unit in extremely humid or wet environments Do not spray water and wet the housing or control panel Do not pull the unit by the cord Always turn the unit of...

Страница 3: ...NOTES ABOUT THE EXHAUST HOSE 8 CONTROL PANEL OVERVIEW 9 USING THE CONTROL PANEL 10 LCD DISPLAY 10 MODE INDICATOR LIGHT 10 POWER BUTTON 10 AUTO RESTART 10 WATER FULL LIGHT 10 REMOTE CONTROL SENSOR 10...

Страница 4: ...n the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your...

Страница 5: ...cation Front View Back View Parts Key 1 Control Panel 2 Air Vent 3 Handle 4 Pre Filter 5 Air Intake 6 Water Outlet Drain 7 Castors 4 8 Continuous Drain Water Outlet for dehumidify mode only 9 Air Outl...

Страница 6: ...nts listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as shown in the followin...

Страница 7: ...ng the grated adapter 1 Insert the round grated adapter through the back grooved side of the window kit plate with hole 2 Secure the grated adapter by fastening the screws from flat side of the window...

Страница 8: ...ide the window kit plate to fit the width of the window You can use screws to secure the window kit plate from sliding 4 Lower the window to secure the window kit in place You may need to use duct tap...

Страница 9: ...s to the exhaust hose A B 5 Attach the connectors to the hose A Extend the ends of the exhaust hose B Thread the duct connector on by turning it clockwise until it stops 20 6 Roll the unit towards the...

Страница 10: ...tioner and start using it Connecting the duct connector to the unit Connecting the duct connector to the grated adapter 7 Align the slots on the duct connector to the tabs and snap into the back of th...

Страница 11: ...en the hose by adding additional hoses or attachments or replace it with any other hose Do not lengthen the exhaust hose by adding additional hoses or attachments Warning Longer hoses are not recommen...

Страница 12: ...anges color to indicate if unit is in Cool mode Blue Light Dehumidify Amber Light or Fan Only mode Green Light Power Button Powers the unit on or off Water Indicator Light The water light will turn on...

Страница 13: ...t The unit is in cooling mode Amber light The unit is in dehumidifying mode Green light The unit is in fan mode Use the Power button to turn the portable air conditioner on and off By default when you...

Страница 14: ...Function Power Powers the unit on or off Fan Speed Sets the fan speed between high medium or low Timer Used to enable the timer Mode Changes between cool dehumidify and fan modes Up Increases the set...

Страница 15: ...Indicator Light on the Control Panel turns blue 4 Select the fan speed by using the Speed button 5 Set the thermostat by using the Up and Down buttons The thermostat is adjustable between 61 F 89 F in...

Страница 16: ...ol while the unit is powered off 2 Use the Up and Down buttons on the remote to set the time displayed in hours you want to pass before the unit turns on After the selected time passes the unit will a...

Страница 17: ...running water below 104 F You may use a mild soap and water solution if needed Allow the pre filter to air dry in a cool and shaded place Dry thoroughly before reinstalling Clean the pre filter period...

Страница 18: ...he timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources d...

Страница 19: ...mer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fan Remove the object from the fan The floor below...

Страница 20: ...t to cool the area or use a larger unit Open windows and doors Close any open doors and windows Too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The...

Страница 21: ...iption of product Portable Air Conditioner Model PAC701W Voltage Frequency AC 115V 60Hz Input Power 650W Current 6 0A Color White Dehumidifying capacity 61 Pints Day Coolant R 410A Timer 24 Hour Dimen...

Страница 22: ...nstruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s ma...

Страница 23: ...m E mail service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar Koldfront products on the w...

Отзывы: