Koldfront PAC10013CBL Скачать руководство пользователя страница 13

 

LED Display 

The LED Display will show the ambient temperature by default.  Pressing either the Up or 
Down button will show the set temperature for 15 seconds, and then revert to the room 
temperature. You can switch between Fahrenheit and Celsius by pressing both the Up and 
Down Buttons simultaneously for three (3) seconds. The displayed range of the ambient 
temperature is from 0º to 99º. Temperatures above 99º will 

be displayed as “Hi”, and 

temperatures below 0º will be displayed as “Lo”. If you enabled the Timer, the LCD Display 
will show the hour(s) set.  

Reservoir Full Light 

In high humidity situations, the internal water reservoir may fill. The unit will automatically shut 
off and the      light will turn on. Once the water is manually drained, the unit will operate 
normally. 
 
To manually drain the water reservoir place a container beneath the water outlet drain and 
unscrew the plug.  Once the water has drained from the unit, be sure to securely replace the 
drain plug. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Caution: Do not drink water drained from the unit. 

Содержание PAC10013CBL

Страница 1: ...Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to https www edgestar com To use the EdgeStar self diagnostic tool go to https support edgestar com P...

Страница 2: ...Do not operate the unit with a damaged plug or loose socket Use only the correct power supply with appropriate amperage If the power cord is damaged it must be replaced by the manufacturer a service...

Страница 3: ...cord into a grounded outlet 2 Press the TEST button on the LCDI plug This should trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit p...

Страница 4: ...rations for Installing the Window Kit 3 Installation 4 CONTROL PANEL OPERATION 6 Using the Control Panel 7 USING THE REMOTE CONTROL 10 Installing the Batteries 11 ENERGY SAVING GUIDE 11 MAINTENANCE 12...

Страница 5: ...s label on the back of your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service un...

Страница 6: ...changer 7 Air Inlet Evaporator 8 Air Inlet Condenser 9 Water Outlet Drain for Continuous Draining Dehumidify and cooling modes only 10 Water Outlet Drain for Manual Draining 11 Exhaust Hose Lock and R...

Страница 7: ...Hose Connector for Window Panel 1 piece 4 Window Plate Hole Cover 1 piece 5 Window Plates 5A 1 piece 5B 2 pieces If you have multiple windows choose one that is near an electrical outlet that will be...

Страница 8: ...rocker switch to the locked position 3 One two or three window plates may be used depending on your window size Panel A can be cut as short as 10 Two plates A and one B can be combined for windows up...

Страница 9: ...window plate A until it locks into place 6 Plug the power cord into the wall outlet and press the reset button The air conditioner is now ready for operation 7 When removing the air conditioner for s...

Страница 10: ...is in cooling mode When in cooling mode the hose must be connected to the unit and the window kit so the unit is venting to the OUTSIDE Dehumidify Mode Indicates unit is in dehumidify mode When in deh...

Страница 11: ...fan speed by using the Speed button 5 Set the thermostat by using the Up and Down buttons The thermostat is adjustable between 61 F 89 F in one degree increments Dehumidifying Mode During the Dehumidi...

Страница 12: ...oling Heating and Fan Only modes Press the Fan button to select the fan speed The LED indicator light next to the High Medium or Low settings will light up Timer The timer can be used to either turn t...

Страница 13: ...99 will be displayed as Hi and temperatures below 0 will be displayed as Lo If you enabled the Timer the LCD Display will show the hour s set Reservoir Full Light In high humidity situations the inte...

Страница 14: ...f Mode The Mode button changes between cool dehumidify heat PAC10013HBL only and fan only modes Fan Speed The Fan Speed button allows you to set the fan speed to high medium or low Timer The Timer but...

Страница 15: ...or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunlight computers servers people etc in the...

Страница 16: ...ble air conditioner ships with a pre filter that will help remove contaminates from the air It is recommended that you clean the filter after every 100 hours of operation Depending on the environment...

Страница 17: ...ower off the unit Then clean and replace the pre filter 4 Unplug and carefully wind the power cord 5 Remove the exhaust hose and duct connectors and keep them in a safe place 6 Remove the batteries fr...

Страница 18: ...s correctly The remote is out of range of the unit Move closer to the unit range is 16 feet or less The remote control is defective Contact customer service My air conditioner is making a loud noise T...

Страница 19: ...op ceiling Use more than one unit to cool the area or use a larger unit There are open windows and doors Close any open doors or windows There are too many heat sources Remove or shut off additional h...

Страница 20: ...013HBL only Current 9 5 A Cooling 9 5 A Heating PAC10013HBL only Cooling Capacity SACC 5600 BTU Cooling Capacity ASHRAE Heating Capacity ASHRAE 10000 BTU 8000 BTU PAC10013HBL Only Color Black and Whit...

Страница 21: ...different standard ASHRAE that produced a higher cooling capacity output While the SACC BTU s are lower than the previous ASHRAE BTU s the construction and cooling capacity of this model s remains unc...

Страница 22: ...ts of God vermin fire flood improper installation unauthorized service maintenance negligence unauthorized installation or modification or rental or commercial use Labor service transportation and shi...