background image

1. Remove the cabinet panels.

NOTE: 

When re-installing the panels, be sure that the screws engage the TOP

panel.

2. Remove the ice chute/drain pan.  Drain tube assembly is packed with the drain

pan as shown below .

3. Install gasketing on top of bin if required.

4.

CAREFULLY 

place the cuber onto the gasketed bin.

5. Install  the  drain  pan/ice  chute.    Route  the  ice  maker  drain  tube  assembly

through the rear of the bin, and clamp the tubing to the drain pan nipple.

6. Electrical, water and drain locations are shown on the following drawing:  

508101502

Rev: 10-5-98

- 3 -

CAUTION:

RISK OF PERSONAL INJURY OR EQUIPMENT DAMAGE

.

Use a suitable lifting means and be careful of sharp edges.

Содержание GT357 Classic

Страница 1: ...GT357 KOLD DRAFT 1525 East Lake Road Erie PA 16511 1088 U S A Phone 814 453 6761 FAX 814 455 6336 2004 KDIndustries Inc Erie PA U S A Printed in U S A 3 04 508 1015 02 English with SI Units A Traditi...

Страница 2: ...PMENT FAILURE OR FIRE Refer all maintenance to qualified personnel Never operate this equipment with covers panels or other parts removed or not properly secured Warn all users to clean up spillage im...

Страница 3: ...top of bin if required 4 CAREFULLY place the cuber onto the gasketed bin 5 Install the drain pan ice chute Route the ice maker drain tube assembly through the rear of the bin and clamp the tubing to t...

Страница 4: ...water supply line 8 Remove the water plate shipping strap 9 Route the bin thermostat capillary tube through the grommet in the right end frame wall and under the ice chute See the diagram below 50810...

Страница 5: ...with PERMANENT CONNECTION TO THE ELECTRICAL SUPPLY fixed supply wiring connection Other operating condition requirements Ice maker ambient air temperature MINIMUM 8o C MAXIMUM 30 C Climate Class N tem...

Страница 6: ...the batch of water then close immediately The water plate should stop when it is fully closed and the water fill cycle will repeat 5 After the water fill is complete move the ICE OFF WASH switch to t...

Страница 7: ...THE FIRST PAGE and the importance of the PREVENTATIVE MAINTENANCE recommendations below PREVENTATIVE MAINTENANCE CLEANING 3 to 6 month intervals depending on water conditions INSPECTIONS During clean...

Страница 8: ...he water system will refill Repeat this dumping and refilling three 3 times to rinse out all of the cleaning solution 7 Mix a sanitizing solution of 60 ml 5 1 4 sodium hypochlorite household bleach or...

Страница 9: ...g the ice maker follow the ice maker cleaning instructions and clean the bin last 6 Replace all enclosure panels before re connecting the electrical supply WINTER CONDITIONING Ice cubers which are idl...

Страница 10: ...508101502 Rev 10 5 98 10...