KOKEN LM-111GM Скачать руководство пользователя страница 4

2

1.   The contents of this instruction manual are subject to change without notice. 
2.   This instruction manual may not be reproduced in part or in its entirety without permission. 
3.   Please contact the manufacturer in the event that any errors or omissions are found in the contents of this 

instruction manual.

4.   This product should be used only as described in this instruction manual. In particular, the product should not 

be used in any way that contravenes the precautions noted in the instruction manual.

The following precautions should be observed when using this product for 

exercises:

1.  This product cannot be used for bathing exercises. Do not immerse the product in water, hot 

water, etc., as this will impair normal use.

2.  If this model is used in airway management training using a tracheal tube or laryngeal mask, first 

spray a lubricant (silicone spray) into the oral cavity of the model and onto the tip of the tracheal 
tube or laryngeal mask.

3.  Lubricant (silicone spray) is not included. Prepare the lubricant in accordance with the following 

precautions.

  ・Use a silicone oil-based lubricant (silicone spray).

 

  Use of a spray containing oil other than grease or silicone oil can damage the model.  Ensure that  
  you use silicone spray.

  ・Use an aerosol lubricant (silicone spray).
  ・ Use the prepared lubricant (silicone spray) after spraying a small amount onto a part of the model 

that does not interfere with its functioning and checking that no problems occur.

4.  Do not attempt mouth-to-mouth artificial respiration, as the inside of the airway cannot be 

disinfected due to the structure of the model.

5.  Air leakage can occur during positive-pressure ventilation using a bag valve mask.
 

Air leakage can be reduced by using an air cushion mask.

6.  Umbilical vein catheterization can be practiced, but do not administer any actual drug solution or 

water, because this model has no drainage function.

7.  Pulling strongly on the umbilical cord or tube for umbilical cord pulsation can damage the model.
8.  The ventilator alarm may continue to sound when using this model with a ventilator attached to 

the flow rate inflatable bag due to the structure of this product.

9.  This product’s application is specific to the Android operating system. Use a tablet PC loaded with 

Android.

10.  The recommended operating environment for the application is Android: 5.0 or later; memory: 

2 GB or more; resolution: 1280 × 720 pixels or higher. The application may not correctly operate 
when using a tablet PC with lower specifications.

11.  If you expect to use the model continuously for several hours, we recommend replacing the 

batteries with new batteries before use. Otherwise the model’s batteries might run out during use.

Содержание LM-111GM

Страница 1: ...lace for easy access Instruction manuals for the Neonatal Resuscitation Simulator Advance in English German French Spanish and Dutch available for download Manufacturer KOKEN CO LTD 1 4 14 Koraku Bunk...

Страница 2: ...1000...

Страница 3: ...pture and leakage of battery fluid Turn off the power of the main body of the model before inserting or replacing batteries 6 Remove the batteries when storing this product Otherwise fluid may leak fr...

Страница 4: ...osol lubricant silicone spray Use the prepared lubricant silicone spray after spraying a small amount onto a part of the model that does not interfere with its functioning and checking that no problem...

Страница 5: ...tion 3 Handling 3 1 Installing the application 3 2 How to pair the model with the tablet PC 3 3 Explanation of screen displays 3 4 Tidying up after use 3 5 Airway management using equipment 3 6 Pulsat...

Страница 6: ...s can be easily controlled on a tablet PC 2 The tablet PC can display the heart rate and SpO2 as a simulated monitor 3 This product is made of a silicone rubber that has a realistic texture and feel 4...

Страница 7: ...repare four AA size alkaline batteries 5 2 Components and Configuration Components Quantity 1 Neonatal Resuscitation Simulator Advance main body Storage bag 1 1 Instruction manual this document The ki...

Страница 8: ...attention to the direction of the positive and negative poles Use AA size alkaline batteries 4 3 Turn on the power of the model s main body by sliding the switch to the ON position When it is activate...

Страница 9: ...lication will not start If pairing cannot be completed successfully try the pairing process again according to the following steps 1 Turn off the power of the main body of the model 2 Close the dedica...

Страница 10: ...as breathing Select from a Respiratory Rate RR of 60 min or 100 min None Model does not produce any lung sounds or crying sounds SpO2 Selected SpO2 value is displayed in Monitor Mode Can select Displ...

Страница 11: ...sks Monitor Mode These buttons can be used to change the SpO2 value No change in plethysmograph if SpO2 is 0 or 20 These buttons can be used to change the HR HR of the main body of the model is also c...

Страница 12: ...bout remaining battery power in the model s main body When the remaining battery power in the model s main body becomes low the red LED lamp next to the power indicator light in the main body of the m...

Страница 13: ...ment using equipment Ensure that you apply a lubricant silicone spray to the tip of the tube and within the oral cavity of the model when using the tracheal tube and laryngeal mask Inserting the tube...

Страница 14: ...ion 5506 Notice for Radio Equipment Hereby KOKEN CO LTD declares that the radio equipment type LM 111GM is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is...

Отзывы: