KOKEN LM-111GM Скачать руководство пользователя страница 12

10

3-4 Tidying up after use

1.   Close applications. Also close this application running in Tasks.

2.  Turn off the power switch of the main body of the model and remove the batteries. Storing 

the model with the batteries left in it may cause battery fluid to leak, etc.

3.  Turn OFF Bluetooth via Configuration on the tablet PC.

  * About remaining battery power in the model’s main body
        When the remaining battery power in the model’s main body becomes low, the red LED    

   lamp next to the power indicator light in the main body of the model lights up. When this  
   happens, please replace the batteries. The model will stop operating about two hours after  
   the red LED lamp lights up.

          
   The model’s operating time depends on the batteries used and the use environment.

- 10 - 

 

 
  3

3-

-4

4   片

片付

付け

け手

手順

順  

  

  1.アプリケーションを閉じます。タスク上で動作している本アプリケーションも閉じてください。 

 

  2.人形本体の電源スイッチを切り、電池を抜き取ります。電池を入れたままの状態で保管した

場合、電池の液漏れなどが生じる恐れがあります。 

 

  3.タブレット PC の設定から Bluetooth をOFFにします。 
 
☆人形本体の電池残量について 

       人形本体の電池残量が少なくなると、人形本体の電源ランプの隣にある、赤色の LED ランプが

点灯します。この場合は電池の交換を行ってください。赤色 LED ランプが表示されてから約2時
間で人形の動作が停止します。 

            

人形の動作時間は、使用する電池や使用環境により変化します。 
 
 
 
 
 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

電池残量が少なくなると
赤色 LED が点灯。 

When the remaining battery 
power becomes low, the red 
LED will light up.  

Содержание LM-111GM

Страница 1: ...lace for easy access Instruction manuals for the Neonatal Resuscitation Simulator Advance in English German French Spanish and Dutch available for download Manufacturer KOKEN CO LTD 1 4 14 Koraku Bunk...

Страница 2: ...1000...

Страница 3: ...pture and leakage of battery fluid Turn off the power of the main body of the model before inserting or replacing batteries 6 Remove the batteries when storing this product Otherwise fluid may leak fr...

Страница 4: ...osol lubricant silicone spray Use the prepared lubricant silicone spray after spraying a small amount onto a part of the model that does not interfere with its functioning and checking that no problem...

Страница 5: ...tion 3 Handling 3 1 Installing the application 3 2 How to pair the model with the tablet PC 3 3 Explanation of screen displays 3 4 Tidying up after use 3 5 Airway management using equipment 3 6 Pulsat...

Страница 6: ...s can be easily controlled on a tablet PC 2 The tablet PC can display the heart rate and SpO2 as a simulated monitor 3 This product is made of a silicone rubber that has a realistic texture and feel 4...

Страница 7: ...repare four AA size alkaline batteries 5 2 Components and Configuration Components Quantity 1 Neonatal Resuscitation Simulator Advance main body Storage bag 1 1 Instruction manual this document The ki...

Страница 8: ...attention to the direction of the positive and negative poles Use AA size alkaline batteries 4 3 Turn on the power of the model s main body by sliding the switch to the ON position When it is activate...

Страница 9: ...lication will not start If pairing cannot be completed successfully try the pairing process again according to the following steps 1 Turn off the power of the main body of the model 2 Close the dedica...

Страница 10: ...as breathing Select from a Respiratory Rate RR of 60 min or 100 min None Model does not produce any lung sounds or crying sounds SpO2 Selected SpO2 value is displayed in Monitor Mode Can select Displ...

Страница 11: ...sks Monitor Mode These buttons can be used to change the SpO2 value No change in plethysmograph if SpO2 is 0 or 20 These buttons can be used to change the HR HR of the main body of the model is also c...

Страница 12: ...bout remaining battery power in the model s main body When the remaining battery power in the model s main body becomes low the red LED lamp next to the power indicator light in the main body of the m...

Страница 13: ...ment using equipment Ensure that you apply a lubricant silicone spray to the tip of the tube and within the oral cavity of the model when using the tracheal tube and laryngeal mask Inserting the tube...

Страница 14: ...ion 5506 Notice for Radio Equipment Hereby KOKEN CO LTD declares that the radio equipment type LM 111GM is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is...

Отзывы: