3.0  ROLLER  BEARING  CONDITION  MONITORING  BY  THE  SHOCK  PULSE 
METHOD (MEAUREMENT METHOD)

3.1   What is Shock Pulse Method (SPM) and it basis

Designation of the Shock Pulse Method (SPM) is a signal processing technique used 

to measure rolling bearing condition and the quality of their lubrication in the motor, 

pumps, separators, turbo compressors for diesel boost, etc. Using the instruments to 

measure shock pulses, one can determine the air or gas leaks via looseness in the 

high-pressure vessels or pipes. The research work conducted at Central Research & 

Design  Institute  of  �avy  allowed  expanding  the  performance  capabilities  of  the 

instruments.  Shock pulse checkers have set to be used for the evaluation of condition 

of high-pressure fuel pumps, diesel injectors, valves of piston compressors. 

The Shock Pulse Method (SPM) was developed by a Swedish instrument company 

and based on monitoring and analyzing of high frequency compression (shock) waves 

caused by mechanical impact. Acceleration of material particles generates pressure or 

shock wave that propagates as ultra-sonic frequency band through the object. In the 

initial phase of impact, the acceleration of material particles depends on impact velocity 

and is independent of the mass of colliding objects. Within short period and there is no 

evident deformation. The value wave shock is the impact velocity of colliding objects. 

In  the  second  phase  of  the  collision,  the  surfaces  of  two  objects  are  deformed;  the 

energy movement declines the object and generates vibrations that are diagnosed by 

the vibration analysis. 

Piezoelectric transducer is used to measure shock pulse; vibration and noise background 

do not effect on it. The transducers electrically and mechanically tune to 28…32 kHz. 

Shock wave caused by the mechanical impact generates the decaying shock vibrations 

in transducer. The maximum magnitude of this decaying vibration is relative to the velocity of 

the impact (v). Since the decaying transient is well defined and has constant decay value, it 

14

Содержание BT-77

Страница 1: ...BT 77 Bearing Tester with Non Contact Tacho Operating Instruction Manual...

Страница 2: ......

Страница 3: ...ng Diagnosis Measurements 2 2 1 Selection and setting up the measuring points 2 2 2 Set up initial parameter taking bearing measurements 2 2 3 Taking bearing diagnosis measurement and save 2 2 4 File...

Страница 4: ...KOHTECT BT 77...

Страница 5: ...for Operation Operating temperature device sensor 10 to 55 5 Relative humidity 80 at temperature 30 Atmospheric pressure 84 to 106 7 KPa 630 800 mm Hg Resonance frequency 32 kHz Measurement unit dBi d...

Страница 6: ...rrect lubrication all these factors cause the collision of the bearing elements and as a result acoustic oscillations of a wide spectrum are generated in the bearing body A specially designed transduc...

Страница 7: ...mplitude over running the value of dBi dBsv features a damage and is used for the evaluation of bearing condition This enable BT 77 to tell the difference of shock pulse values induce is low shock and...

Страница 8: ...um value At the measurements the bearing checker allows to filter out and measure two specified values of the shock acceleration amplitude the Carpet value dBc and the Max value dBm The dBc background...

Страница 9: ...of the shock acceleration amplitude measurement for drives bearings can be influenced by shocks produced during the running in of a gear mesh which can be transferred onto the bearings However mostly...

Страница 10: ...attery power supply socket for the measuring probe and USB port for tachometer sensors or file upload to PC for data management The controls and connectors location is shown on the Fig 1 2a Fig 1 2b F...

Страница 11: ...y and Measuring Modes To switch ON the BT 77 bearing tester press The device perform self test as shown in Fig 2 1 and automatically enter the first default operation mode USB interface Fig 2 2 To con...

Страница 12: ...account the following and see Fig3 3 Metal column between the probe tip and bearing must be if possible straight don t take readings from the cap that covers the bearing housing It is critical that t...

Страница 13: ...the D input value and go to next setting parameters Screen will display RPM shaft rotating speed setting same using or key to set and press to confirm The display now shows Single Average or Contin se...

Страница 14: ...t on machine place the probe firmly against the machine at the desired measurement location and ready to take reading Press and wait until bearing reading is displayed While taking the reading display...

Страница 15: ...en data file for review press or to go to my documents screen and press to see file and directory as Fig 2 6 Press or to move cursor to data file with b77 extension and press to open for view 2 3 Eval...

Страница 16: ...ts Bearing 3 is in good technical condition Condition of bearing 4 is getting worse after the measurement dated 15 03 90 the lubrication was replaced no positive results were shown it is advisable to...

Страница 17: ...away to the mark surface this will decrease fault response from the surface of the shaft surface Use retro reflecting tape as a mark It is possible to use the correction fluid Stroke to apply the mar...

Страница 18: ...of high frequency compression shock waves caused by mechanical impact Acceleration of material particles generates pressure or shock wave that propagates as ultra sonic frequency band through the obj...

Страница 19: ...e moment when a bearing needs replacement Because of the very large dynamic range shock pulses are measured on a decibel scale Empirical tests showed that even the new and lubricated bearing generates...

Страница 20: ...background of the bearing However under the work of the bearing the peak strikes have not only varying magnitudes but frequencies as well Fig 3 2 shows the typical examples of the evaluation of bearin...

Страница 21: ...ncreasing dBc 10 even there are not any defects on the outer raceway of a the bearing The Max Value and the Carpet Value are relatively close dBm 30 dBc 20 4 Under pump cavitation both backgrounds fea...

Страница 22: ...ble within some time interval bearing condition is acceptable 3 4 Method and measurement location of the bearings Shock pulse measurements should be completed on the bearing housing When free access t...

Страница 23: ...Fig 3 3d 4 0 Delivery Set Description Qty Note 1 BT 77 w rechargeable battery inserted 1 2 Bearing Vibration measuring probe 1 3 IR Tachometer w mounting stand 1 4 AC Charger 220 230Volts 1 5 Liquid...

Отзывы: