![KOHTECT BT-77 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/kohtect/bt-77/bt-77_operating-instructions-manual_1990242014.webp)
KOHTECT BT-77
diameter or shaft diameter “D” and RPM, “N” speed for the machine.
ATTENTION!
Measurement calculation method:
single reading with dB
i
taken into account. Result – normalized value of
dB
m
, dB
c
for condition evaluation based on the technology developed
by the Central Research & Design Institute of Navy.
continuous reading with dB
i
taken into account. Result updates every
seconds. Press “STOP” button to end the procedure.
five readings are taken with dB
i
taken into account; the result is their
arithmetic mean value.
2.2.3 Taking bearing diagnosis measurement and save
After identified the measuring point on machine, place the probe firmly against the
machine at the desired measurement location and ready to take reading.
Press
and wait until bearing reading is displayed. While taking the reading,
display show “busy…” message, Fig. 2.5a, and the measuring cycle is
approximately 30-40 second if “Average” method is selected.
Once measurement finish, the display shows Fig-5b, the measuring results: the
Max value, Carpet value (
dB
m
and dB
c
) and condition of the bearing evaluated
on dB
n
chart as final result.
Fig-2.5a Fig-2.5b
To save the reading, Press
follow
OK key to enter main directory.
Press
again to make new directory, save, read or delete folder or press
Single -
Cont. -
Average -
•
•
d B m =
2 9
S a t i s f .
d B c =
1 8
= = = = = = = = = = = = = = = =
D = 2 5 N = 3 0 0 0
d b i = 3 0 A v e r a g e
Max. value
Bearing evaluation
Carpet value
Input info
B u s y . .
•
•
10