ROUGH-IN PLUMBING

Turn off the water supply.

Install or relocate the supplies and outlets as necessary
to conform to the roughing-in dimensions. For shut-off
valve location, see Fig. #3.

3. INSTALLATION

INSTALL NEW SHUT-OFF VALVE

For supply installation, refer to the instructions packed
with the supply stop.

Locate the supply shut-off valve so it is 10-1/4” above the
floorline, and 5-3/4” to the left of the centerline of the clos-
et flange.

Fig. #3

5-3/4”

10-1/4”

12”

Install new 5/16” diameter T-bolts.

Fig. #4

Closet Flange

T-Bolts

INSTALL TOILET GASKET

Position the toilet upside down on padding.

Firmly attach the gasket around the toilet outlet. If you are
using a gasket with an integral plastic sleeve, position the
gasket with the sleeve facing away from the toilet.

If desired, place a 1/4”-thick bead of toilet setting com-
pound around the toilet base.

NOTE: If a rag or other plug was placed in the closet
flange, remove the rag before setting the toilet.

Fig. #5

Gasket

ALIGN AND SET TOILET

Carefully align and lower the toilet over the closet flange
and T-bolts.

CAUTION: Risk of external leakage. Do not lift or
rock the toilet after placement. A new gasket must
be reapplied if you break the watertight seal.

Apply full body weight to the toilet rim to set the seal.

Fig. #6

Содержание WELLWORTH WATERGUARD K-3520

Страница 1: ...e dimensions are nominal and conform to tol erances by ANSI standards A112 19 2 PRODUCT REQUIREMENTS Since all toilets do not have the same supply rough in you may have to change the location of the s...

Страница 2: ...fixture for any sign of damage before removing the existing toilet Turn off the water supply Flush the toilet and sponge out all remaining water from the tank and bowl Disconnect the supply valve and...

Страница 3: ...T Bolts INSTALL TOILET GASKET Position the toilet upside down on padding Firmly attach the gasket around the toilet outlet If you are using a gasket with an integral plastic sleeve position the gasket...

Страница 4: ...duct damage Overtightening may cause breakage or chipping of the vitreous china bowl or tank Fig 8 Tank Bolt Gasket Washer Brass Nut CONNECT SUPPLY SHUT OFF VALVE NOTICE Read this section carefully be...

Страница 5: ...ke sure the refill tube is inserted into the overflow tube Check that the water level is at the water line inside the toilet tank If the level is off hold the middle of the float rod and carefully ben...

Страница 6: ...e plunger 3 Valve does not shut off and water is flowing A Defective plunger A Replace plunger and water is flowing into the overflow NOTE After tank is filled to water level line turn off sup B Water...

Страница 7: ...Co distributor please write us directly at Kohler Co Attn Customer Service Department 444 Highland Drive Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your claim including a...

Страница 8: ...8 106128 2 AA A Kohler Co Kohler WI...

Отзывы: