background image

111864-2-

BA

 (-)

Copyright 

1996 Kohler Co.

WELLWORTH

 LITE

VITREOUS CHINA

REVERSE TRAP TOILETS

BEFORE YOU BEGIN

HOW TO USE THESE INSTRUCTIONS

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your partic-
ular installation. This will aid you in avoiding the unneces-
sary expense associated with improper installation. In
addition to proper installation, read all operating and safe-
ty instructions.

All information in these instructions is based on the latest
product information available at the time of publication.
Kohler Co. reserves the right to make changes in product
characteristics, packaging, or availability at any time with-
out notice.

These instructions contain important care, cleaning, and
warranty information - please leave instructions for the
consumer.

NOTES

Seat post holes on 5-1/2” centers.

Water depth from rim is 6-11/16”.

1-3/4” passageway.

Ensure that the new toilet has the correct
roughing-in dimension. The K-3407 has a 10”
roughing-in dimension. See Fig. #1.

Be very careful while working with vitreous china
products. Vitreous china can break and chip if
you overtighten bolts and nuts or carelessly
handle the product.

Carefully inspect new fixture for any sign of
damage.

Observe all local plumbing and building codes.

Shut off hot and cold water supplies.

For new construction, refer to the dimensions in
Fig. #1 and Fig. #4 for locating the shut-off valve.

Fixture dimensions are nominal and conform to
tolerances by ANSI Standards (A112.19.2).

WARNING: Risk of external leakage. The fill
valve nut has been factory-tightened to design
specifications. If re-tightening is required, wrench
tighten one turn past finger tight.

ORDERING INFORMATION

Bowl K-4229
Tank K-4512

When specified:

3/8” supply

K-7638

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

Floor bolts (pr.)

21401

. . . . . . . . . . . . . . . . . . . . . . . . . 

Recommended elongated seat

K-4652

. . . . . . . . . . . 

Содержание WELLWORTH LITE K-4229

Страница 1: ...e leave instructions for the consumer NOTES Seat post holes on 5 1 2 centers Water depth from rim is 6 11 16 1 3 4 passageway Ensure that the new toilet has the correct roughing in dimension The K 3407 has a 10 roughing in dimension See Fig 1 Be very careful while working with vitreous china products Vitreous china can break and chip if you overtighten bolts and nuts or carelessly handle the produ...

Страница 2: ...wdriver Toilet gasket wax seal Toilet T bolts 2 5 16 diameter Toilet supply shut off valve 3 8 recommended If existing toilet does not have a shut off valve below the tank install shut off valve before installing new toilet See Page 3 ROUGHING IN 29 3 8 15 Fig 1 3 8 I P S SUPPLY C L OF OUTLET FRONT OF BOWL K 4229 ET BASE 1 19 3 4 17 5 16 4 5 16 9 1 2 4 1 8 9 31 15 16 3 5 8 10 ...

Страница 3: ...scard NOTICE If a new toilet is not installed immediately temporarily stuff a rag in the closet flange Fig 2 Closet Flange Install new 5 16 diameter T bolts Fig 3 T Bolts Closet Flange TO INSTALL NEW SUPPLY SHUT OFF VALVE Install toilet supply shut off valve so it is 9 above floorline and 4 1 8 to the left of the centerline of the closet flange Centerline of supply shut off outlet should extend 4 ...

Страница 4: ...ses washers and nuts on exposed T bolts Hand tighten nuts then tighten additional 1 2 turn with wrench CAUTION Overtightening may cause breakage or chipping If T bolts extend more than 1 4 from top of nut cut off ex cess Wipe away any residue Install bolt caps Fig 6 Nut Washer Bolt Cap Base Bolt Cap TO INSTALL NEW TANK Make sure the three tank bolts extend fully through the holes in the gasket Set...

Страница 5: ...tightened to design specifications If re tightening is required wrench tighten one turn past finger tight Fig 8 Tubing Ferrule Supply Shank Seal Washer Coupling Nut Compression Nut Shut Off Valve Tubing Ferrule Supply Shank Compression Washer Coupling Nut Compression Nut Shut Off Valve Turn shut off valve on and check for leaks If connections are squarely assembled a slight retightening of the nut...

Страница 6: ...ew times Clean float valve seal surface located under float valve cap Replace float valve cap assembly by engaging lugs and rotating 1 8 turn clockwise Turn water on Install filter in supply line to prevent recurring problems B Replace seal 3 Incorrect water level height A Valve float cup does not contain enough water to provide required ballast A During fill cycle hold float under water a few sec...

Страница 7: ...ler Distributor and the KOHLER TECHNICAL SPECIALIST THIRD If you are unable to obtain warranty service through either your contractor or Kohler Co distributor please write us directly at Kohler Co Attn Customer Service Department Kohler WI 53044 U S A FOURTH Include all pertinent information regarding your claim including a complete description of the product model numbers colors finishes and the ...

Страница 8: ...8 111864 2 BA Kohler Co Kohler WI ...

Отзывы: