background image

   

                                                                               

     1075723-2A-D                                

                                                                                                                    4   

  

   

                                                                               

     1075723-2A-D                               

                                                                                                                     5   

  

How to Install the Tube assy

Insert the tube(22) into the tube assy(20) ,Tighten the screw(23) with 

hex wrench(24).

From top of the shower panel, the first handle controls shower head. 

The handle opens with one-quarter turn counter-clockwise. The 

second one controls watertiles. The operation is the same as the first 

one. The third one controls handspray. The operation is the same as 

the first one. The last one controls temperature, The temperature is 

set by slowly turning the temperature handle. For safety reasons, 

there is a stop that limits temperature to 38°C. To get a higher 

temperature, push the button and continue turning the temperature 

selector.

How to Install the Shower Head

Install the regulator of shower head as required (shown in regulator             

installation instruction). Put the washer (25) into shower head (26, not 

for 3866T) connector. Thread the shower head onto the tube 

assy(22), tighten with strap wrench.

Install the Handspray 

Connect the hose(29) to elbow outlet(28). Connect the hose to 

handspray(27, not for 3866). Tighten all the nuts. Hang the handspray 

on the shower bracket(19).

The height of bracket can be adjusted by pressing the pinch cock and 

sliding up and down.

Nip the hose in the gap between shelves and the extrusion.

HANDLE OPERATION

CARE AND MAINTENANCE

Clean Thermostatic Cartridge

Very hard water can obstruct the filters on thermostatic cartridge and 
reduce the flow of water. Please clean the cartridge as follows:

Shut off  the water supplies of the faucet and open the flow valve, 

then proceed to remove the cartridge. The cartridge is sense organ, 

please be careful.

Disassemble the upper and down covers. Loosen the butterfly nut. 

Hang the hook. Take out the shower panel and hold it on wall fixture 

bracket.

Make sure the handle faces backwards before your action. Remove 

the temperature handle kit: Remove the temperature handle cap(34), 

unscrew the screw(33) with screwdriver. Take off the washer(32) and 

the temperature handle kit(31).  Unscrew the screws(30) with 3mm 

hex wrench(Fig.20). Take out the temperature valve kit(35). Remove 

stop assembly(36). Removing the thermostatic cartridge(37) 

cautiously(Fig.22). Clean the thermostatic cartridge by soaking it in 

warm vinegar.

After cleaning, install the "stop assembly" back to the cartridge, 

adjusting the stop pin into the notch(Fig.22). Install the cartridge and 

stop assembly into the body(38), adjusting the stop pin into the notch 

of the body(Fig.23). Reinstall the temperature valve kit. Secure it by 

screws(30). Reinstall the temperature handle kit. Reinstall the shower 

panel and the upper & down covers as previous procedure.

20

22

23

24

Fig.16

22

25

26

Fig.17

Fig.18

Fig.15

22

Fig.19

20

27

19

29

22

28

Fig.20

30

31

32

33

34

Fig.21

35

38

37

36

Notch

Stop pin

Fig.22

Fig.23

Notch

Stop pin

Содержание Waterlite tower 3866

Страница 1: ...ONS ROUGH IN DIMENSIONS 1368 809 Shower Panel OPERATION CONDITION Dounting Dimensions 225 300 143 812 Supply Pipes Handspray Not for 3866 G3 4 530 736 51 3866 3872 SHOWER PANEL PIPES Shower Head Not for 3866 1100 65 150 Floor of bath room 65 243 57 G1 2 280 280 G3 4 455 30 30 G1 2 Recommended mounting height Planform Inlet Elbows 3010558 Tube Assy 3008557 Shower Head Not for 3866 3008426 Clamp 832...

Страница 2: ...40 HOT COLD 150mm Fig 1 Fig 2 1 2 1 3 Disassemble Upper and Lower Covers Unscrew the screws 1 with screwdriver Take off the upper cover 2 and the lower cover 3 Fig 3 5 4 Fig 4 20 40 Fig 5 Fig 6 Ø8 Ø8 150 Supply connnectors 8 9 10 7 6 6 3007327 Shelf 3008256 Elbow Connector F G1 2 3008520 Screw 3008555 Handspray Not for 3866 1046290 Hex Wrench 3008144 Scraper 3010558 Tube Assy 3007160 Cap 837192 Sc...

Страница 3: ...ke sure the bracket level and secure Refer to Fig 8 Apply tape or thread sealant to threads of G3 4 fittings 6 Install the inlet elbows 13 onto the fittings Outlets of the elbows facing downwards Turn on the main water supply Run water for about one minute to remove any debris Support the lower base 16 of the shower panel onto wall fixture bracket 12 referring to Fig 12 Hang the hook 14 which atta...

Страница 4: ...ND MAINTENANCE Clean Thermostatic Cartridge Very hard water can obstruct the filters on thermostatic cartridge and reduce the flow of water Please clean the cartridge as follows Shut off the water supplies of the faucet and open the flow valve then proceed to remove the cartridge The cartridge is sense organ please be careful Disassemble the upper and down covers Loosen the butterfly nut Hang the ...

Отзывы: