How to Install the Tube assy
Insert the tube(22) into the tube assy(20) ,Tighten the screw(23) with
hex wrench(24).
From top of the shower panel, the first handle controls shower head.
The handle opens with one-quarter turn counter-clockwise. The
second one controls watertiles. The operation is the same as the first
one. The third one controls handspray. The operation is the same as
the first one. The last one controls temperature, The temperature is
set by slowly turning the temperature handle. For safety reasons,
there is a stop that limits temperature to 38°C. To get a higher
temperature, push the button and continue turning the temperature
selector.
How to Install the Shower Head
Install the regulator of shower head as required (shown in regulator
installation instruction). Put the washer (25) into shower head (26, not
for 3866T) connector. Thread the shower head onto the tube
assy(22), tighten with strap wrench.
Install the Handspray
Connect the hose(29) to elbow outlet(28). Connect the hose to
handspray(27, not for 3866). Tighten all the nuts. Hang the handspray
on the shower bracket(19).
The height of bracket can be adjusted by pressing the pinch cock and
sliding up and down.
Nip the hose in the gap between shelves and the extrusion.
HANDLE OPERATION
CARE AND MAINTENANCE
Clean Thermostatic Cartridge
Very hard water can obstruct the filters on thermostatic cartridge and
reduce the flow of water. Please clean the cartridge as follows:
Shut off the water supplies of the faucet and open the flow valve,
then proceed to remove the cartridge. The cartridge is sense organ,
please be careful.
Disassemble the upper and down covers. Loosen the butterfly nut.
Hang the hook. Take out the shower panel and hold it on wall fixture
bracket.
Make sure the handle faces backwards before your action. Remove
the temperature handle kit: Remove the temperature handle cap(34),
unscrew the screw(33) with screwdriver. Take off the washer(32) and
the temperature handle kit(31). Unscrew the screws(30) with 3mm
hex wrench(Fig.20). Take out the temperature valve kit(35). Remove
stop assembly(36). Removing the thermostatic cartridge(37)
cautiously(Fig.22). Clean the thermostatic cartridge by soaking it in
warm vinegar.
After cleaning, install the "stop assembly" back to the cartridge,
adjusting the stop pin into the notch(Fig.22). Install the cartridge and
stop assembly into the body(38), adjusting the stop pin into the notch
of the body(Fig.23). Reinstall the temperature valve kit. Secure it by
screws(30). Reinstall the temperature handle kit. Reinstall the shower
panel and the upper & down covers as previous procedure.
20
22
23
24
Fig.16
22
25
26
Fig.17
Fig.18
Fig.15
22
Fig.19
20
27
19
29
22
28
Fig.20
30
31
32
33
34
Fig.21
35
38
37
36
Notch
Stop pin
Fig.22
Fig.23
Notch
Stop pin