background image

5. Install the water pipe to the connecting pipe at the side of

the tank for water supply.

NOTE:

1. Ensure inlet valves of frame should be shut down.

2.

It is recommended that a temporary rubber or plastic

hose is attached to the stop valve, and the water supply

line should be flushed clean of dirt and debris.

5.

4. Connect the drainage pipe to the drainage hole as shown.

4.

3.

NOTE:

Ensure the tank to remain level.

3.

ConnectingPipe

WaterPipe

连接管

自来水编织管

Drainage Hole

排污口

Drainage Pipe

排污管

将水箱放置到合适位置,对准固定架上的螺丝孔和地面上
的两个膨胀螺钉,如图

A

用内六角扳手把六角长螺丝拧紧。

注意要保持水箱架的水平。

如图

B

用扳手拧紧可调支架上的膨胀螺钉的螺母、弹性垫

片和垫片。

注:

1.

确保水箱内部进水角阀为关闭状态。

2

.建议在连接供水时

,

在角阀上连接一个临时橡皮或塑料软

管,冲洗供水管道,确保水干净,管道内无沙石、垢污等。

Spanner

Adjustable Bracket

Hex Pan

Tighten

Loosen

Hexagonal Screw

Level

B

A

水平尺

六角长螺丝

内六角扳手

扳手

可调支架

Put the frame to the desired location, fixation of the 

screw holes on the ground and the expansion of the 

two Bulge Screw, Tighten the hexagonal long screw 

with hex pan as shown in Fig. A. Please ensure the 

frame remains level.

Tighten the screw of adjustable brackets with hex 

pan as shown in Fig. B.

-4-

1359749-T01-A

Содержание VIA K-20629T-BW

Страница 1: ...K 20630T BW K 19720T W 200 K 20007T VABW K 4141T 2P 300 K 20645T BW K 19720T W 300 K 20010T VABW K 4141T 2P 300 K 20648T BW K 19720T W 300 K 4179T VABW K 4141T 2P 100 K 20649T BW K 19720T W 100 K 628...

Страница 2: ...1 Fixture dimensions are nominal and conform to tolerances established by ASME Standards A112 19 2 2013 This product complies with GB 25502 2017 Water Efficiency Grade 1 140mm 50mm 1 ASME A112 19 2 2...

Страница 3: ...SKU of faceplate INSTALLATION Fig 2 2 1 1 2 3 2 SET THE SPACING OF THE BOWL After you install the tank be careful to set the spacing of set aside the length for carrier studs and tighten nut The bowl...

Страница 4: ...a little after it is installed to prevent water storage See Fig 4 See Fig 5 3 1 2 3 4 4 5 Fig 4 4 Fig 5 5 Inlet Outlet 1 4 INSTALL THE NEW TOILET 1 Install the accessory kit into the installing hole...

Страница 5: ...ners Products containing chlorine calcium hypochlorite can seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for...

Страница 6: ...tallation with spares not provided by Kohler Function Explanation 2010 Copyright Kohler China Ltd 2010 1955 200444 Advantages Of Touchless In wall Tank Advanced tank spares flush volume refer to senso...

Страница 7: ...r per flushing 6 0L 6 0L 5 0L 3 0L 3 5L 3 5L K 6281T VE2 NA K 6281T VES2 NA K 6281T ESS NA Large flushing volume Small flushing volume Power Temperature Sensing distance 220V 50 60Hz 5 8 seconds after...

Страница 8: ...n in Fig A Tighten the bolts with medium Allen key as shown in Fig B adjust the height of the adjustable bracket in compliance with customer s requirements and then tighten the nut with hex pan Based...

Страница 9: ...e pipe to the drainage hole as shown 4 3 NOTE Ensure the tank to remain level 3 ConnectingPipe WaterPipe Drainage Hole Drainage Pipe A B 1 2 Spanner Adjustable Bracket Hex Pan Tighten Loosen Hexagonal...

Страница 10: ...nnector and output connector or product may be damaged 6 16 20 AC AC220V B Installation of Rectangular Shield Knife Cover 2 Install the rectangular shield in the block screen of the tank and tighten t...

Страница 11: ...liminate unwanted rectangular shield with a sharp knife 6 Rectangular Shield Big Filtration Cap Small Filtration Cap Big Filtration cap Small Filtration cap Long Screw 3 Fix the motor wire panel conne...

Страница 12: ...Pipe Outlet Pipe C Installation of Toilet 1 Install the inlet pipe and outlet pipe to the lavatory as shown and mark on the pipes at the back side of the tank with a ruler and a pencil and reserve ap...

Страница 13: ...tration and use a spirit level to ensure the lavatory to remain level 5 Spirit Level 4 48mm 58mm of the long screw shall be reserved outside the wall as shown in the illustration If the long screw out...

Страница 14: ...the requirements of installation dimensions And make sure the long screw would not bump any other parts D Installation of Cover 2 Fix the adjustable board to the wall by tightening the lock nut as sh...

Страница 15: ...nect the connectors and take down the cover NOTE Before disassembly please close the input valve firstly Cover Lock Cover AdjustableBoard a b 5 As illustrated make the locker of panel aim at locker of...

Страница 16: ...table board as shown 4 3 Tighten the locknut to the marked position of OPEN to take out the adjustable board 3 OPEN Locknut Adjustable Board Adjustable Board Long Screw 2 2 Loosen the long screw as sh...

Страница 17: ...d take them out 5 String Screw 5 Take motor wire out of the soft belt release the two screws that locked the box NOTE Screws will not quit easily just feeling that the screw is threaded out is enough...

Страница 18: ...rasp the top of the inlet valve and push back 9 Pipe Top Inlet Valve 10 Hole the pole bracket with your hands as shown Then take out the pole bracket by pulling it 10 Pole Bracket 8 8 Remove the lock...

Страница 19: ...ck on or off by hand Move the lock on and open the cover then the outlet valve can be loosen Note 11 Open Lock A Wash Filtration Net Close corner valve first then loosen and take out the tighten nut a...

Страница 20: ...tank by adjusting the control pole Turn the control pole counterclockwise to lower down the floating box and reduce the water level of the tank Turn the control pole clockwise to hoist the floating b...

Страница 21: ...with clean water 1 Long screw is tighten too far 2 Pole lock is not locked tight enough with the reversed lock 1 Loosen the long screw make sure the sign the long screw accords with the hole on refer...

Страница 22: ...4 5 6 7 8 9 10 11 12 13 4 5 6 7 8 9 10 11 12 13 17 1359749 T01 A...

Страница 23: ...zardous materials used in this product The product service life for environment protection is 10 years Kohler Company will specify product service life based on product characteristics The product ser...

Страница 24: ...10 10 GB T 26572 GB T 26572 Pb Hg Cd Cr VI PBB PBDE 19 1359749 T01 A...