TROUBLE SHOOTING PROCEDURES
TROUBLE SHOOTING PROCEDURES
如按以上操作仍未解除故障,请通过经销商与本公司联系。
1.
检查电源连接
2.
清理物体
3.
清洁窗口
I the trouble remains after above-mentioned actions are taken, please contact with us via distributor.
按钮被箱体内电线卡住
打开面板,重新布线
1.
排水阀未能装紧在排水头上
2.
排水阀封水片有杂物
3.
电机盒摆杆卡住
1.
重新拧紧排水阀(参照
15
页)
2.
排水阀封水片
3.
将电机盒取下,并手动将摆杆置于复位状态
(参照
18
页)
1.
进水角阀没有打开
2.
进水阀的浮筒被水箱壁顶住
3.
进水阀的浮筒被杂物粘住
1.
把进水角阀打开(参照
14
页)
2.
调整浮筒到合适位置
3.
应用水清洗干净浮筒
1.
长螺杆拧得过前
2.
杠杆扣与倒扣没有扣紧
1.
旋转长螺杆,使长螺杆标记对上固定孔(参照
9
页)
2.
重新扣紧杠杆扣与倒扣
按钮卡住
(
15 )
不出水
(感应指示灯不闪烁)
1.
无电或接线错误
2.
感应范围内有其他物体一直被感应
3.
感应窗口较脏
无水流出或出水较差
(感应指示灯闪烁)
1.
接插件松动
2.
水路不通
3.
电机控制盒故障
4.
大冲拉杆、小冲拉杆与杠杆扣没有扣紧
1.
检查接插件连接
2.
检查水路
3.
检查电源连接是否正常,并断开电源输入
2
秒后重
新上电
4.
将大冲拉杆、小冲拉杆与杠杆扣扣紧
No water fills in via inlet
valve
No drainage when
pressing the heavy and
slight drainage button
Leak of the toilet and
squat
Symptoms
Probable Causes
Recommended Action
1. The outlet valve is not installed tight enough
with the outlet hole.
2. The rubber gasket of the outlet valve is blocked
by waste.
3. Swing pole of the motor box is stucked.
1. Retighten the outlet valve (refer to page 15)
2. Clean the rubber gasket of the outlet valve.
3. Remove the motor box and place the swing
pole manually to reset position.(See Page 18).
1. The inlet valve is closed
2.
Floating box of inlet valve is blocked by tank wall
3.Floating box of inlet valve is block by waste
1. Open inlet valve(refer to page 14)
2.
Adjust floating box to appropriate position
3. Wash the floating box with clean water
1. Long screw is tighten too far.
2. Pole lock is not locked tight enough with the
reversed lock.
1. Loosen the long screw, make sure the sign
the long screw accords with the hole on
(refer to page 9).
2. Relock the pole lock with the reversed lock.
Water level of the inlet valve is not appropriate
Too high or too low water
level
Readjust water level (refer to page 15)
No flushing
(Indicator not flashing)
1. No power or mistake connected.
2. There is an object within the sensing distance.
3. The sensing window needs cleaning.
1. Check the power connect.
2. Remove the object or reduce the sensing
distance.
3. Clean the window.
No flushing or poor
flushing while the indicator
can flash
1. Connector is loosen.
2. Waterway is jammed
3. Motor box assy. is break.
4. Long flush lever and short flush lever are not
linked to the leverage properly.
1. Check connector for connection.
2. Check the waterway
3. Make sure the power supply normal, and
plug off the power cord connector, Re-plug
in after 2 sec.
4. Tighten the link of long flush lever, short
flush lever and the leverage.
The button was stuck.
The button was stuck by wire in the power box.
Open the cover, arrange the layout of wire
again.
-16-
1359749-T01-A