-2-

TOOLS AND MATERIALS REQUIRED
(Not supplied)

·

·

·

·

·

·

·

·

·

·

·

·

254mm (10") adjustable wrench
305mm (12") pipe wrench
Metal file (file cut)
Tape measure
Tubing cutter
Level
Hacksaw
Putty knife
Screwdriver
Toilet gasket (wax seal)
Toilet T-bolts (2), 8mm (5/16") diameter
Toilet supply shut-off valve, 10mm(3/8 ) recommended

If the existing toilet does not have a supply shut-off

valve below the tank, install one before installing the new
toilet.

"

The flexible hose needed is supplied. The stop valve and wax
ring are not supplied.

NOTICE:

·

·

254mm
305mm

60cm

·

·

·

·

·

·

·

·

·

·

8mm

T

2

10mm

WARNING: Risk of personal injury or product
damage

WARNING: Risk of external leakage

: Handle vitreous china products very carefully.

Vitreous china can break and chip if you overtighten
bolts and nuts.

. The fill valve

nut has been factory-tightened to design specifications.
If re-tightening is required, wrench tighten one turn
past finger tight .

Unit: mm

:

Reference Value

K-23188T-NS

FRONT OF BOWL

Finished Wall

Supply

229

200

395

OF OUTLET

C

L

305

700

378

748

299

286

1392769-T01-A

Содержание User Manual K-23188T-NS

Страница 1: ...re Furefresh QC Seat K 23205T 305mm K 23188T NS 400mm K 23189T NS K 23204T K 23205T 1 Copyright Kohler China Investment Co Ltd 2019 2019 No 2 KOHLER ROAD SANSHUI CENTRAL INDUSTRIAL PARK LEPING TOWN SANSHUI DIST FOSHAN GUANGDONG PRC POST CODE 528137 2 528137 8 MENGSHAN RD ECONOMIC DEVELOPMENT ZONE OF HUANTAI ZIBO SHANDONG CHINA 256410 8 256410 NO 1 KOHLER STREET ECONOMIC DEVELOPMENT ZONE OF FAKU CO...

Страница 2: ... toilet The flexible hose needed is supplied The stop valve and wax ring are not supplied NOTICE 254mm 305mm 60cm 8mm T 2 10mm WARNING Risk of personal injury or product damage WARNING Risk of external leakage Handle vitreous china products very carefully Vitreous china can break and chip if you overtighten bolts and nuts The fill valve nut has been factory tightened to design specifications If re...

Страница 3: ...ot use white cement or high lime content cements to install this toilet The expansion of cement due to a rise in temperature may make the toilet crack or cause damage Kohler is not responsible for any damage caused by installation with the use of cement Closet Flange 67mm 229mm 200mm Fig 3 3 TO INSTALL SUPPLY SHUT OFF VALVE Install the supply shut off valve so it is 229mm above the finished floor ...

Страница 4: ... gasket should not be installed at temperatures less than 21 C If you are using a toilet gasket with an integral plastic sleeve make sure the gasket is positioned with the sleeve facing away from the toilet NOTE 1 NOTE 2 o 1 21 2 o C Install brackets Plastic Trap Outlet Toilet Gasket Fig 8 8 Install plastic to ground and mounted with 3 set of bolts firmly not supplied 3 NOTE Must use the toilet in...

Страница 5: ...ig 10 10 Take hose guide apart and slide onto the supply hose with the flared end last Slide the two inserts into the flared end of the hose guide Insert into toilet wall and tighten nut Fig 11 11 Hose Guide Fig 12 12 Carefully align and lower the bowl Apply weight to the bowl rim to let the outlet insert into plastic trap Outlet Plastic Trap 5 1392769 T01 A ...

Страница 6: ...etely to prevent damage shank by forced connection Supply Shank Supply Shut Off Valve Fig 15 15 IMPORTANT Make certain the top is turned to the locked position Valve may not turn on if top is not fully in the locked position Before turning on the supply valve for the first time follow the steps below to clear sand debris and rust from the system Make sure water sure water supply is off Remove valv...

Страница 7: ...is at the marked water line Test flush the toilet Check all connections for leakage for several days Set the tank cover in place on the tank PUSH BUTTON INSTALLATION NOTE Remove the package and screw out the nut Make the button through the tank cover as shown Be noted that the button shall be kept level Arrange big and small flush buttons according to the label of water consumption on the tank Tig...

Страница 8: ... debris or replace the piston seat washer assembly D Remove the tank and tighten the flush valve nut if flush valve gasket is leaking Do not overtighten If leakage continues replace the gasket E Adjust the tank water level if it is too high 2 No Flush IMPORTANT Use only genuine Kohler parts as shown to avoid property damage 4 Tank takes excessive time to fill 5 There is excessive noise when the ta...

Страница 9: ...an seriously damage fittings in the tank This damage can cause leakage and property damage Kohler Company shall not be responsible or liable for any damage to these tank fittings caused by the use of cleaners containing chlorine calcium hypochlorite WARNING Risk of property or product damage Please do not use hard materials like scouring pad to clean product surface especially the product logo CAU...

Отзывы: