ROUGH-IN DIMENSIONS (23861T & 23749T)

 The Finished Floor

   

                                                                          

1387024-2A-E           

                                                                                                                                         6

  

CLEANING INSTRUCTIONS

Stop pin

Notch

2. Remove the screw(31) and adapter spline(32), and 

then unscrew the nut(34) and stopper(33). Remove 

the cartridge cautiously. Clean the thermostatic 

cartridge by soaking it in warm vinegar. 

2

Cartridge

3

4

Notch

Stop pin

5

Groove

Round mark

6

26

29

30

31

32

28

31

32

33

34

1

Number 37

26

29

30

28

Recommended Height

1000~1

100

All Finishes: Clean the finish with mild soap and warm water. Wipe entire surface completely dry with clean soft cloth. 

Many cleaners may contain chemicals, such as ammonia, chlorine, toilet cleaner etc. which could adversely affect the 

finish and are not recommended for cleaning.
Do not use abrasive cleaners or solvents on Kohler faucets and fittings. 

3. After cleaning, install the “stop assembly” back on 

the cartridge, adjust the stop pin into the notch.

4. Install the assembly cartridge and stop in the body, 

adjust the stop pin into the notch.

5. 

NOTE: 

Do not turn the cartridge when reinstalling it. 

If you turned it accidentally, you should adjust it and be 

sure that the round mark is correctly in line with the 

groove, or readjust as per the steps of verification and 

setting.

6. Install the adapter spline(without turning the spindle). 

Ensure the indicator line on the adapter spline align with 

the indicator line on the stopper. Tighten the screw(31) 

with a screwdriver. Install the temperature handle(28). 

Ensure the number 37 on temperature handle is upward 

vertically(After assembly, it could not be turned counter-

clockwise if not pushing the button). Tighten the screw 

(29) with 2.5mm hex wrench(26). Insert the plug(30).

Clear the Thermostatic Cartridge

 

Very hard water can obstruct the filters on the thermostatic cartridge and reduce the water flow. Please clean the cartridge 

as follows: Shut off the water supply of the faucet and turn on the water flow valve, then proceed to remove the cartridge. 

The cartridge is sensitive part, please be careful.

1. Before your action, make sure the number 37 on the 

temperature handle is upward vertically(It could not be 

turned counter-clockwise if not pushing the button). 

Remove the temperature handle(28).

Indicator line

Upward 

horizontally

46

167

302

150±10

40

Ø37

440

15

20

11

19

1035

882

75

49

127

31º

G1/2˝

149

Ø42

126

233

283

450

335

23749T-9 Showerhead

23861T-9 Showerhead

24