Страница 1: ...R Tea For Two Whirlpool Baths K 852 V AB K 852 JA AA 111889 CA 1093 Copyright E1993 Kohler Co...

Страница 2: ...cted by a qualified licensed electrician For J1 and JA models only A green colored terminal or a wire connector marked G GR GROUND or Grounding is provided within the terminal compartment To reduce th...

Страница 3: ...60 Hz 11 Field Wiring Control Box Compartment 230 V 50 Hz 11 Connect Control Box 230 V 50 Hz 12 WATER TEST WHIRLPOOL ELECTRONICS 12 COMPLETE FINISH WALL 12 COMPLETE INSTALLATION 13 Install Handles an...

Страница 4: ...required protected with Class A Ground Fault Circuit Interrupter 60 Hz or ELCB 50 Hz Pump control 120 V 15 A 60 Hz or 230 V 15 A 50 Hz C PRODUCT INFORMATION Fixture basin area top area weight Bathing...

Страница 5: ...lation including the following Product Requirements NOTICE Follow all local plumbing and electrical codes B FACTORY ASSEMBLED FEATURES K 852 V Factory installed components include pump with integral t...

Страница 6: ...tened D CONNECTIONS AND SERVICE ACCESS Before installation ensure proper access to the final connections NOTICE Provide unrestricted service access to the pump An access panel 20 W x 15 H minimum must...

Страница 7: ...sealant C CLEARANCE REQUIREMENTS Check roughing in and room dimensions in order to provide adequate available space for the bath unit D NEW OR REPLACEMENT INSTALLATION REQUIREMENTS This bath unit can...

Страница 8: ...educe the risk of water damage C STUD POCKET PREPARATION Construct a recess designed for your particular installation Framing is of 2 x 4 construction When constructing framing allow for thickness of...

Страница 9: ...s 6 BEFORE INSTALLING UNIT A TILING IN BEAD INSTALLATION Before setting bath an optional tiling in bead is recommended to be applied to whatever side of the bath contacts the wall Refer to Ordering In...

Страница 10: ...ommodate the piping Metal Shims Metal Shim B INSTALL PLUMBING CAUTION Risk of damage to whirlpool bottom and subfloor Ensure watertight seal on bath drain connections 1 When whirlpool is securely posi...

Страница 11: ...mpleted at the factory A licensed electrician must install a GFCI protected 120 Volt 15 Amp grounded outlet Your whirlpool may then be plugged into this outlet No other load should be on this circuit...

Страница 12: ...to a level at least 2 above the top of the highest jet Operate whirlpool for 5 minutes and check all whirlpool harness piping connections for leaks For additional information on whirlpool operation s...

Страница 13: ...r installation do not use abrasive cleaners as they may scratch and dull the module surface Use warm water and one of the liquid detergents to clean the surface Stubborn stains paint or tar can be rem...

Страница 14: ...the top of the highest jet Water temperature in the whirlpool should not exceed 104_F 40_C Bath Wall 2 Minimum Water Line Jet Trim B OPERATING SEQUENCE Refer to chart for proper operating sequence 1...

Страница 15: ...unterclockwise to open are not functioning B Trim kit installed incorrectly B Reinstall trim kit checking for damage to O Ring C Jets are blocked C Remove blockage 3 Motor turns water is pumping but A...